Thread lead wires and safety cable from 

motor assembly through downrod.

Install downrod. Slip downrod into motor 

housing yoke, aligning holes and install cross 

pin and keeper pin. 

Insert cross pin through yoke and downrod 

until point appears on the other side, and 

insert keeper pin on cross pin. 

Pull the downrod up tight against the cross 

pin, and then evenly tighten the downrod set 

screws on motor housing yoke. 

Warning

: Cross pin and keeper pin must be 

installed securely, failure to install them will 

result in serious injury.

Place top cover, downrod sleeve, 

decorative ring and canopy over downrod, 

and then replace the hanger ball with pin 

and set screw. Tighten it securely. 

Warning

: Make sure the 

pin

 is installed 

well on hanger ball with downrod. 

Note

: For the downrod sleeve, make sure 

the side with an “UP” label is installed 

upward. The label is removable.

Note: Downrod sleeve is not available if 

use the shorter 4” downrod 

Install ball end of downrod into mounting 

bracket opening. Align (engage) slot on 

ball with tab on mounting bracket.

Warning:

 Failure to align slot on ball with 

tab may result in serious injury.

Important

: If using the angle mount, 

make sure open end of mounting bracket 

is installed facing the higher point of the 

ceiling and make sure the ceiling angle is 

not steeper than 15º. Longer downrod 

may be necessary allowing the fan blades 

to rotate without obstructions.    

For Canadian installation and for USA fan 

and light kit combinations over 35 lbs, in 

both flush and downrod modes the safety 

cable must be installed into the house 

structure beams using 3” lag screws, 

washers and lock washers provided. 

Make sure that when the safety cable is 

fully extended the lead wires are longer 

than the cable and no stress is placed on 

the lead wires.

Note

: If Installing The Secondary Support 

Safety Cable in the U.S., Do Not Remove 
Knockouts In The Outlet Box.

  

Make wiring connections using wire connectors provided as indicated above.  

Brown wire from fan to Brown wire from receiver marked Motor U.

Gray wire from fan to Gray wire from receiver marked Motor V.

Orange wire from fan to Orange wire from receiver marked Motor W.

White wire from fan marked “For light” to White wire from receiver marked “For light”.

Blue wire from fan marked “For light” to Blue wire from receiver marked “For light”.  

White (Neutral) wire from house to White wire from remote marked AC IN N. 

Black (Live) wire from house to Black wire from remote marked AC IN L. 

Connect all green grounded wires to Grounded wire from House. 

Make sure that no filaments are outside of the wire connectors.

Insert the remote receiver into mounting bracket.

After making the wire connections, the wires should be spread apart with the grounded conductor 

and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor 

on the other side of the outlet box. The splices after being made should be turned upward and 

pushed carefully up into the outlet box.       

Cross pin

Keeper pin

Pin

Canopy

Decorative ring

Downrod sleeve

Tab

Slot

SAFETY CABLE INSTALLATION

Lag screw

Safety cable

Washer

Lock washer

Orange

Brown Grey

White

White

Black

Black

Receiver

White

Blue

Ground/Green

Ground/Green

Wall switch

Power source

Top cover

UP

Summary of Contents for 3ALBR60 D Series

Page 1: ...AME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 3ALBR60XXXD Series Fan cETL Model N...

Page 2: ...35 lbs or less And Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Remove K...

Page 3: ...he slotted holes on the canopy upper ring Remove the other 2 set screws Save screws Use metal outlet box suitable for fan support and use only the screws provided with the outlet box must support 35 l...

Page 4: ...h flush and downrod modes the safety cable must be installed into the house structure beams using 3 lag screws washers and lock washers provided Make sure that when the safety cable is fully extended...

Page 5: ...se till lock Reinstall the other screw Tighten all screws securely Loosen 2 and remove 1 preassembled screw from light pan Save screw for later use Connect white wire from fan to white wire from LED l...

Page 6: ...for 30 seconds then automatically change to 5th 4th 3rd 2nd 1st at intervals of 30 seconds and then change it from Low speed 1st to 2nd 3rd 4th 5th 6th repeat the cycle until the breeze mold is cancel...

Page 7: ...magnetic metal materials by a magnet built in the transmitter Wall mount cradle Tips for end users 1 If your fan is operated automatically after installation and power on it is because your fan is sti...

Page 8: ...late are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point...

Page 9: ...Feb 2021...

Reviews: