42 1/3/02
3 lnstallation and Setup
Parameter Setting and Adjustment
1.
[Splice Src]
(Splice source)
Set up the source for the splice level.
Note:
splice level from the front of the cabinet and external splice level cannot be
used at the same time.
2.
[Splice Del]
(Splice delay)
In the event of delay from activation of the knife signal to the cutting of the web, this
time can be set up within this parameter.
3.
[Splice Lev]
(Level from splice menu parameter)
[Splice Src = S. Lev]
The level for the splice is set up in the menu parameter for
[Splice Lev]
. A new
output level is needed when the knife cuts the web. The new output level depends
upon the diameter of the new roll. New rolls will typically be about the same diameter,
in which case the level can be constant. To compensate for different setpoints, this
output level varies in proportion to the setpoint. (Output =
Splice Lev
x setpoint)
[NONE]
Set up if splice is not used.
[S. Lev]
(Splice level is source.) With
[S. Lev]
as the source, the
splice level is set up in a menu parameter. Choose this
source if the diameter of the new roll is about the same at
every splice.
[ANALOG]
(Analog source) With
[ANALOG]
as source, the splice level
comes from an analog signal (0-10V). The analog signal can
either be wired on terminal 51, or come from a potentiometer
on the front panel in the cabinet version (see drawing below).
Choose this source for large changes in the diameter of the
new roll.
X-3000
10
K
+10V
Splice level 0-10V
0 V
Splice level
input 0 - 10V
50
51
52
+10V
10 K
0 V
board
Main
X-3000
board
Front panel
1.6
1.3
1.1
Operator
&
control
panel
50
20
80
100%
0
50
20
80
1 00%
0
MANUEL/
AUTO
TENSION
OFF/ON
AUT O
MANUEL
OUTPUT
Type:
X3 000 -ce-UW
SN: 34 55
Supp lyvoltage:
1 15/230V 60/50 Hz
Supp lycurre nt:
< 0.5A
50
20
8 0
100 %
0
WD042.dsf
Diagnostic
Password
Setup Menu
Mode Menu
Run Mode
Amplifier
0/4mA
Language
Gain
Ratio
P Level
D Level
Softs Menu
Start Out
Softs Lev.
Softs Time
Hold Level
Anti Menu
Anti.Src.
Anti Max
Anti Min
Anti Slope
Splce Menu
Splice Src
Splice Del
Splice Lev
Splice Tim
WebBr Menu
Webbr Lev.
Webbr Time
Range Exp.
RE Source
Ranges
Start No.
Dn Level
Up Level
Range Time
Brake Menu
Range Dia Menu
Dia. Menu
Diamet.Src
P/Rev Roll
mm/Pulse
Min Diam.
Max Diam.
Fac. Diam
DF AutoSet
New Roll D
Diameter
Output2 Menu
Out2 Src
Out2 Slope
Out2 Scale
Out2 Off