![Montavlo X-3000ce-UW Installation And Operating Instructions Manual Download Page 36](http://html1.mh-extra.com/html/montavlo/x-3000ce-uw/x-3000ce-uw_installation-and-operating-instructions-manual_1829726036.webp)
36 1/3/02
3 lnstallation and Setup
Stop signal is activated
When input is activated by 24 VDC, output increases to a higher level and then starts
to regulate again. The level is set by the anticoast level parameter.
Anticoast is factory-set to use
Source = OUTPUT
.
Possible sources for anticoast:
Examples for which diameter source is best when production:
• Requires large rolls and low tension
• Uses a great variety of materials
Note:
set up and adjust diameter parameters in the diameter menu.
Electrical Wiring
Here is a typical example of how to connect the fast stop.
[OUTPUT]
The torque required for fast stop is calculated internally by
the controller from the setpoint and the output. The result
is a calculated diameter that can be scaled by an
adjustable factor that fits the machine's actual rampdown
time.
[DIAMETER]
In some applications, the correct diameter cannot be
calculated from setpoint and output. In such instances,
diameter should be chosen as source.
Diagnostic
Password
Setup Menu
Mode Menu
Run Mode
Amplifier
0/4mA
Language
Gain
Ratio
P Level
D Level
Softs Menu
Start Out
Softs Lev.
Softs Time
Hold Level
Anti Menu
Anti.Src.
Anti Max
Anti Min
Anti Slope
Splce Menu
Splice Src
Splice Del
Splice Lev
Splice Tim
WebBr Menu
Webbr Lev.
Webbr Time
Range Exp.
RE Source
Ranges
Start No.
Dn Level
Up Level
Range Time
Brake Menu
Range Dia Menu
Dia. Menu
Diamet.Src
P/Rev Roll
mm/Pulse
Min Diam.
Max Diam.
Fac. Diam
DF AutoSet
New Roll D
Diameter
Output2 Menu
Out2 Src
Out2 Slope
Out2 Scale
Out2 Off
START
STOP
K100
K100
+24V
DI8 / Anticoast
1
2
3
4
5
6
7
8
9
1
0
30
3
1
3
2
3
3
3
4
3
5
36
3
7
3
8
3
9
K100
1 (COM)
2 (NC)
MACHINE
START
(fast stop)
WD003.dsf
Stop signal
1
0
Run mode
Stop mode
Time
Run mode
Speed
Machine
0 %
100 %
Anticoast
mode
SD005.dsf