W28A
bi-amped, active loudspeaker system
12
ENGLISH
Wiring of the power cable for the
PowerCon
®
connector
(supplied with the unit)
:
Strip the cable for 20 mm of length and strip each wire for
8 mm of length. We suggest to use a power cable with
1,5 ÷ 2 mm
2
section wires (the insert terminals can however
support a cable with wires up to a section of 4 mm
2
/12AWG).
Insert the power cable into the bushing and into the chuck
(white chuck for a cable diameter of 5 ÷ 11 mm; black chuck
for a cable diameter of 9.50 ÷ 15 mm).
Fit a ferrule at the end of each wire and connect wires on
the insert.
The wire ends can be clamped in the terminals using an Allen
wrench or soldered to the terminal. Always paying attention
to the symbols shown on the connector: L (Live - correspon-
ding to the brown wire), N (Neutral - corresponding to the
light blue wire) and (Ground - corresponding to the yellow
and green wire).
After connecting the wires to the insert, lead the cable
through the housing and screw down the bushing.
Important !
SETSCREWS
N
L
INSIDE
VIEW
INSERT
CABLE
WIRES
20 mm
8 mm
Power supply connection:
• Make sure that the mains voltage corresponds to
the voltage indicated on the rear panel, under the mains
socket.
POWER
CON
®
CONNECTOR
HOUSING
BUSHING
CHUCK
CABLE
FERRULES
FOR
STRANDS
WIRES
• Use only the factory supplied mains cable or, if a different
plug style is needed, a suitable cable with a ground
connection and marked with the safety approvals valid in
the country of use.