9
INSTALLATION
GAS CONNECTION
Before connecting the range and fryer battery to the gas supply line, be sure that all
new piping has been cleaned and purged to prevent any foreign matter from being carried into
the controls by the gas. In some cases, filters or drops are recommended. A separate Gas
Shut Off Valve must be installed upstream from the range and fryer battery and located in an
accessible area.
WARNING
CAP ALL UNUSED OPEN ENDS OF THE GAS SUPPLY MANIFOLD
It is important that adequately sized piping be run directly to the point of connection at
range and fryer battery with as few elbows and tees as possible. Consult local gas company
for proper piping size and gas pressure.
PIPE JOINT COMPOUND OR THREAD SEALANT THAT IS USED SHOULD BE
RESISTANT TO ACTION OF LIQUEFIED PETROLEUM GASES. USE SPARINGLY
AND ONLY ON MALE THREADS.
Turn Gas Shut Off Valve “ON” and immediately check carefully for gas leaks. Do this before
attempting to operate the range and fryer battery.
TEST ALL PIPE JOINTS FOR LEAKS BEFORE OPERATING BROILER(S) OR ANY OTHER
APPLIANCE. THIS INCLUDES ALL GAS CONNECTIONS THAT MAY HAVE LOOSENED
DURING SHIPMENT. USE A RICH SOAP SOLUTION (OR OTHER ACCEPTED LEAK
TESTER) AROUND ALL PIPE CONNECTIONS AND ALL OTHER JOINTS.
DO NOT USE
AN OPEN FLAME.
ABSOLUTELY NO LEAKAGE SHOULD OCCUR, OTHERWISE, THERE
IS A DANGER OF FIRE OR EXPLOSION DEPENDING UPON CONDITIONS. NEVER USE
IF LEAKAGE IS DETECTED.
NEVER OPERATE THE BURNER WITH AN EMPLY FRYPOT. IT ONLY TAKES A FEW
MINUTES TO COMPLETELY RUIN A FRYPOT THIS WAY, AND THE FRYTOP WAR-
RANTY WILL BE VOID.
ADJUSTMENTS
The burner used on the fryer is a patented design which does not require primary air
adjustment.