The home theater high definition revolution is in full swing. Modern HDTVs and digital audio equipment offer 
stunning picture and sound with a level of precision that was impossible just a few years ago. Unfortunately, high 
definition digital AV components are just as vulnerable to dirty AC power and surge problems as their predecessors.

As a long-time audiophile and serious home theater enthusiast, I always knew problematic AC power could seriously 
degrade picture and sound quality. Ordinary unfiltered AC power contains electromagnetic and radio frequency noise 
that degrades the picture and sound quality of your home theater. Monster PowerCenters feature patented Monster 
Clean Power

 filter circuitry that virtually stops the electromagnetic pollution that goes right through typical 

surge protectors. Clean Power circuitry  filters both external AC powerline noise and also dramatically reduces 
noise generated by AV equipment connected to the PowerCenter.

The HDP1800 incorporates Monster HD Clean Power filters, which are specifically engineered for today’s digital high definition 
components. This reflects our commitment to creating performance-enhancing solutions for the latest audio and video equipment so 
you can enjoy the best HD picture and digital sound quality from modern home theater systems. The HDP1800 also provides complete protection and filtering 
for legacy analog and high power AV components.  

These days, home theater components are better than ever, providing thrilling and dramatic digital sound and razor sharp high definition picture. We know your 
new HD PowerCenter will help bring it all together with Clean Power and superior surge protection. With Monster Power you’ll enjoy the best possible sound 
and picture, and that’s what high definition home theater is all about.

Noel Lee,

The Head Monster

Noel Lee

A NOTE FROM THE HEAD MONSTER

Summary of Contents for HDP 1800

Page 1: ...Owner s Manual Manuel du propri taire HDP1800 High Definition PowerCenter PowerCenter Haute D finition...

Page 2: ......

Page 3: ...The Monster PowerCenter Design 5 Monster HDP1800 PowerCenter Features 6 Hook Up Guide 8 High Definition Digital Outlets 8 Analog Audio Outlets 9 Ultra High Current Audio PLC Compatible Outlets 10 Coax...

Page 4: ...i...

Page 5: ...If you use rooftop devices such as satellite dishes antennas or any other component with wire that connects to your PowerCenter be sure r be sure r the wire s is properly grounded This protects again...

Page 6: ...owner s manual for important details CAUTION Exposure To Heat Do not expose your PowerCenter to direct sunlight or place it near wall heaters space heaters or any enclosed space prone to temperature i...

Page 7: ...ainst electrical surges every AC power cable coaxial cable network line and phone line in the system must be connected to an appropriate PowerCenter outlet or port Important Note Proper Protection and...

Page 8: ...l surge protectors Clean Power circuitry filters both external AC powerline noise and also dramatically reduces noise generated by AV equipment connected to the PowerCenter The HDP1800 incorporates Mo...

Page 9: ...onster HD Clean Power filters and Clean Power Stage 2 circuitry which filters both AC powerline noise and reduces noise generated by your connected equipment Monster Clean Power Stage 2 features two u...

Page 10: ...to these potentially damaging levels ultra fast T2 auto disconnect protection circuitry shuts down the Monster PowerCenter for 15 seconds When the under voltage or over voltage condition returns to no...

Page 11: ...s also debuted the first high end surround sound processor with THX certification Tony currently heads up the R D team at Monster Cable where he continues to develop advanced products with cutting edg...

Page 12: ...6 MONSTER HDP 1800 POWERCENTER FEATURES HDP 1800 FRONT VIEW HDP 1800 REAR VIEW 12 15 12 11 10 9 8 4 2 1 3 13 14 16 6 5 18 7 17...

Page 13: ...lets 9 High Definition Digital Filter Unswitched Outlets 10 Analog Audio Filter Unswitched Outlets 11 Ultra High Current Audio Filter Switched Outlets FRONT 12 Phone Line Surge Suppression 13 Satellit...

Page 14: ...component s power cord HDTV DVD etc into the PowerCenter s corresponding outlet For components not listed determine if they are audio video high definition digital or ultra high current audio compone...

Page 15: ...Plug each component s power cord Receiver Processor etc into the PowerCenter s corresponding outlet For components not listed determine if they are audio video digital or ultra high current audio and...

Page 16: ...let For components not listed determine if they are audio video digital or ultra high current audio and use a corresponding outlet for best performance IMPORTANT NOTES It does not harm analog audio vi...

Page 17: ...nnected to the PowerCenter s Cable TV coaxial connection Connecting a Satellite or other cable to the PowerCenter s Cable TV connection may result in compromised reception Protect TV Cable and Satelli...

Page 18: ...d Network Connections as follows NOTES The HDP1800 is not intended for hook up of any phone which carries two separate phone lines on a 4 pin RJ11 jack To ensure complete power surge protection all li...

Page 19: ...ctive Try turning on the light switches located near the wall outlet Too many devices are connected causing an overload tripping the Thermal Circuit Breaker Press the PowerCenter Thermal Circuit Break...

Page 20: ...ugged into a switched outlet won t receive power when the PowerCenter is turned On unless the component power is also switched On Turn the component power On Speakers emit a humming or buzzing noise T...

Page 21: ...your cable or satellite provider to correct your installation The PowerCenter is emitting a loud buzzing alarm The PowerCenter protection circuitry has sacrificed itself to protect connected equipment...

Page 22: ...Line Ground L G Neutral Ground N G Total Energy Dissipation 5 526 Joules Clamping Level TVSS Voltage 330 Volts PLC Outlet Supression Voltage is 400 500V max Steady state clamping voltage is 330V Dime...

Page 23: ...roduct and viii without a connection in a daisy chain fashion to or with any extension cord surge suppressor power strip uninterruptible power supply UPS or other equipment Authorized Dealer means any...

Page 24: ...at the time when You received the Product from an Authorized Dealer and that causes a failure of the Product to perform in accordance with Monster s documentation accompanying the Product unless such...

Page 25: ...r should have discovered it if such Product Defect was obvious and before the end of the Warranty Period for Product Defects applicable to the affected Product then Monster will provide You with one o...

Page 26: ...governing the sale of consumer goods including without limitation national laws implementing EC Directive 44 99 EC OTHER RIGHTS THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO...

Page 27: ...many 0800 1819388 France 0800 918201 Netherlands 0800 0228919 Belgium 0800 79201 Norway 800 10906 Denmark 8088 2128 Sweden 020 792650 Finland 800 112768 Italy 353 65 6869354 FURTHER PROCEEDINGS Monste...

Page 28: ......

Page 29: ...HDP1800 PowerCenter Haute D finition Manuel du propri taire...

Page 30: ......

Page 31: ...erveaux derri re la conception du PowerCenter de Monster 33 Caract ristiques de Monster HDP1800 PowerCenter 34 Guide de raccordement 36 Prises num riques haute d finition 36 Prises audio analogiques 3...

Page 32: ......

Page 33: ...avec un c ble branch votre PowerCenter assurez vous que les c bles sont correctement mis la terre Cela vous prot gera contre les Center assurez vous que les c bles sont correctement mis la terre Cela...

Page 34: ...ce manuel de l utilisateur pour les d tails importants ATTENTION Exposition la chaleur N exposez pas votre PowerCenter la lumi re directe du soleil et ne le placez pas pr s des calorif res des source...

Page 35: ...e quipement contre les surtensions lectriques chaque c ble coaxial d alimentation en c a chaque ligne de r seau et chaque ligne t l phonique du syst me doit tre reli une prise ou une porte appropri e...

Page 36: ...magn tique qui passe travers les protecteurs typiques de surtension Les circuits de filtrage Clean Power filtrent la fois le bruit sur l alimentation c a et aussi r duisent le bruit g n r par votre pr...

Page 37: ...s qui filtre la fois le bruit sur l alimentation c a et r duit le bruit g n r par votre propre quipement Clean Power Stage 2 offre des filtres isol s ultra avanc s optimis s pour les quipements audio...

Page 38: ...32Vrms Lorsque l alimentation atteint l un de ces niveaux potentiellement dangereux le circuit de protection ultra rapide T2 teint le PowerCenter de Monster pendant 15 secondes Lorsque la tension rede...

Page 39: ...avec certification THX Tony dirige pr sentement l quipe de R D chez Monster Cable o il continue de d velopper des produits avanc s avec des caract ristiques de fine pointe Richard Marsh Richard a d ve...

Page 40: ...34 CARACT RISTIQUES DE MONSTER HDP1800 POWERCENTER HDP1800 VUE AVANT HDP1800 VUE ARRI RE 12 15 12 11 10 9 8 4 2 1 3 13 14 16 6 5 18 7 17...

Page 41: ...prises commut es 9 Prises filtres num riqueshaute d finition non commutables 10 Filtre audio analogique non commutables 11 Filtre audio de puissance prises commut es VUE AVANT 12 Suppression des surt...

Page 42: ...entation de chaque appareil HDTV DVD etc dans la prise correspondante du PowerCenter Pour les appareils non indiqu s sur la liste voyez s ils correspondent au type audio vid o num rique haute d finiti...

Page 43: ...ntation de chaque appareil r cepteur processeur etc dans la prise correspondante du PowerCenter Pour les appareils non indiqu s sur la liste voyez s ils correspondent au type audio vid o num rique ou...

Page 44: ...Pour les appareils non indiqu s sur la liste voyez s ils correspondent au type audio vid o num rique ou audio haute puissance et branchez les dans la prise correspondante pour obtenir le meilleur r s...

Page 45: ...devrait tre branch e la connexion coaxiale de c ble TV du PowerCenter Brancher un c ble Satellite ou autre la connexion c ble TV du PowerCenter peut compromettre la r ception Prot gez les connexions d...

Page 46: ...Prot gez les connexions t l phoniques et r seau comme suit REMARQUES Le HDP1800 n est pas pr vu pour connecter un t l phone deux lignes sur un connecteur 4 pins RJ11 Pour assurer la protection compl t...

Page 47: ...de la prise murale Trop d appareils sont connect s sur le PowerCenter causant ainsi une surcharge qui d clenche le disjoncteur thermique Appuyez sur le disjoncteur thermique du PowerCenter pour l encl...

Page 48: ...e recevra aucune alimentation lorsque le le PowerCenter est allum moins que l appareil soit aussi allum Allumez l appareil Les haut parleurs mettent un bourdonnement Le PowerCenter partage son aliment...

Page 49: ...votre fournisseur de c ble ou de satellite pour v rifier votre installation Le PowerCenter met une forte alarme bourdonnante La circuiterie de protection du PowerCenter s est sacrifi e pour prot ger...

Page 50: ...igne Terre L G Neutre Terre N G Dissipation d nergie totale 5 526 Joules Niveau de calage Tension TVSS 330 Volts Prise CPL Tension supression est 400 500 V max Tension calage tat permanent est 330 V D...

Page 51: ...agr implique tout distributeur revendeur ou d taillant qui i tait d ment autoris faire affaire dans la juridiction o il vous a vendu le produit ii tait autoris vous vendre le produit selon les lois d...

Page 52: ...n employ e par Monster d un accident autre qu un mauvais fonctionnement qui serait traduit par un d faut du produit e la maintenance ou la r paration du produit par une personne non employ e par Monst...

Page 53: ...t pas commercialement pratiquable ou ne peut pas tre faite au bon moment DOMMAGES L QUIPEMENT CONNECT Monster vous offrira galement une solution concernant les dommages l quipement connect si i vous a...

Page 54: ...SP CIFIQUES ET VOUS POURRIEZ AVOIR D AUTRES DROITS QUI VARIENT D UNE PROVINCE L AUTRE CETTE GARANTIE S TEND SEULEMENT VOUS ET NE PEUT PAS TRE TRANSF R E OU ASSIGN E Si une disposition de cette garanti...

Page 55: ...0 0569520 Alemagne 0800 1819388 France 0800 918201 Pays Bas 0800 0228919 Belgique 0800 79201 Norv ge 800 10906 Danemark 8088 2128 Su de 020 792650 Finlande 800 112768 Italie 353 65 6869354 AUTRES PROC...

Page 56: ...untries 2008 Monster LLC 7251 West Lake Mead Blvd Las Vegas NV 89128 USA 1 877 800 8989 Monster Technology International Ltd Ballymaley Business Park Gort Road Ennis Co Clare Irlande 001 866 348 4171...

Reviews: