background image

 
 
 

 

Z-Wave® 700 Series Door/Window Sensor 

 

P/N 43303 

User's Manual

 

 

Summary of Contents for Z-Wave 700 Series

Page 1: ...Z Wave 700 Series Door Window Sensor P N 43303 User s Manual ...

Page 2: ... not place or install this device in an area where it can be exposed to excessive amounts of dust humidity oil smoke or combustible vapors Do not expose this device to excessively high temperatures Do not place it in on or near heat sources such as a fireplace stove radiator etc Do not leave it in direct sunlight Remove the battery from the device if it will go unused for a lengthy period of time ...

Page 3: ...detects when it is opened or closed and sends a Z Wave trigger signal to the network These trigger signals can be used to activate various other devices and perform preprogrammed tasks When the sensor is included into a secured Z Wave network all communications will be encrypted This device supports the Security S0 Security S2 Unauthenticated and Security S2 Authenticated protocols CUSTOMER SERVIC...

Page 4: ...contents to ensure you have all the items listed below If anything is missing or damaged please contact Monoprice Customer Service for a replacement 1x Door Window Sensor 1x Magnet 1x CR2032 Battery 1x Strip 3M Tape 1x DSK Card 1x User s Manual PRODUCT OVERVIEW ...

Page 5: ...ver of the sensor is removed the LED will blink once and a Wake Up Notification is sent after 10 seconds INCLUSION AND EXCLUSION Note If you are installing a complete Z Wave system for the first time refer to the installation guide of your Z Wave Controller before installing this sensor Inclusion Put your controller into Inclusion Mode and follow its instructions for adding the sensor To put the s...

Page 6: ...into SmartStart Inclusion Mode While in this mode the sensor can be added to a Z Wave controller that supports SmartStart Exclusion To remove the sensor from your network put your Z Wave controller into Exclusion Mode and follow its instructions to delete the sensor from the controller Ensure the rear cover is closed firmly then trigger the reed switch 3 times in 5 seconds to send the NIF for excl...

Page 7: ...command classes from the controller and sending a Wake Up Notification message after 10 seconds If the sensor receives a Wake Up No More Information command it will go into sleep mode after 10 seconds It will process all the commands after sending the Wake Up Notification AUTO WAKE UP Use the Wake Up command to setup the waking time and send the Wake Up Notification to the controller You can then ...

Page 8: ...cally Notification command and will reset to its factory default settings Note that this should only be done if the controller is inoperable or otherwise unavailable OVER THE AIR FIRMWARE UPDATES This sensor supports Over the Air OTA Firmware Updates Refer to your controller s manual for OTA update instructions Once the OTA update is complete you should reset the sensor to its factory default sett...

Page 9: ...There is a DSK label on the rear cover Scan the DSK label to access SmartStart if the gateway s UI supports SmartStart A Security Enabled Z Wave Controller must be used to get the most out of this sensor This device supports the Security S0 Security S2 Unauthenticated and Security S2 Authenticated protocols Z WAVE COMMAND CLASSES COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 COMMAND_CLASS_ASSOCATION_V2 CO...

Page 10: ...MULTI_CHANNEL_ASSOCIATION_V3 Z WAVE S2 SUPPORT COMMAND CLASSES COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 COMMAND_CLASS_ASSOCATION_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 COMMAND_CLASS_INDICATOR_V3 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 COMMAND_CLASS_NOTIFICATION_V8 COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_...

Page 11: ...ee live online technical support to assist you with any questions you may have about installation setup troubleshooting or product recommendations If you ever need assistance with your new product please come online to talk to one of our friendly and knowledgeable Tech Support Associates Technical support is available through the online chat button on our website www monoprice com or through email...

Page 12: ... N 43303 Protocol Z Wave Plus V2 Series 700 Frequency 908 42 MHz Battery Type 1x CR2032 Wireless Speeds 9 6 40 100 kbps Outdoor Wireless Range Direct Up to 200 meters Outdoor Wireless Range Max Hop Repeat Up to 800 meters Indoor Wireless Range Direct Up to 100 meters Indoor Wireless Range Max Hop Repeat More than 300 meters Operating Temperature 5 140 F 15 60 C Dimensions 2 2 x 1 0 x 0 2 56 x 26 x...

Page 13: ...ent has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfe...

Page 14: ...y Canada This Class B digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada Monoprice and all Monoprice logos are trademarks of Monoprice Inc Z Wave and the Z Wave logo are registered trademarks of Z Wave Alliance Inc in the United States and other countries 3M and the 3M logo are registered trademarks of 3M Company ...