Association
ALL-ON AND ALL-OFF COMMANDS
Depending upon your primary controller, the Monoprice Z -Wave®
Switch can be set to respond to All-On and All-Off commands in
one of four different ways. Some controllers may not be able to
change the response from its default setting. Please refer to your
controller's instructions for information on whether or not it
supports the configuration function and if so, how to change the
setting.
1. It will respond to All-On and All-Off commands (default).
2. It will not respond to All-On or All-Off commands.
3. It will respond to All-Off commands, but will not respond
All-On commands.
4. It will respond to All-On commands, but will not respond
All-Off commands.
Grouping ID Max number of Nodes Descriptions
1
1
Lifeline: Send device reset locally notification
2
5
StatusReport: Send basic report
3
5
AssGroupSet: Send Basic set command