75
ENGLISH
SETTINGS
DISPLAY
The "DISPLAY" menu allows:
Regulation of Display contrast
Activation/Deactivation of backlight.
Enabling/disabling of acoustic signal.
Set the timer to turn off the Display
backlight.
Set the timer to turn off the Display (sleep
mode).
To set:
OK > SETTINGS > DISPLAY.
STAND-BY
The STAND-BY function is used if the stove needs to be turned off immediately or the modulation
via an additional thermostat is required. The display will feature the word STAND-BY which indicates
the active function.
To set:
OK > SETTINGS > STANDBY.
STAND-BY FUNCTION SET TO ON
When the STAND - BY. function is active (ON), if the room temperature exceeds the set value plus
DELTA T OFF
, the stove will switch off after
a pre-set (default) delay period, and STAND - BY will be displayed on the screen.
When the room temperature is lower than the set value less
DELTA T ON
and the stove has cooled, it will start to work again at the set power,
and work will be displayed on the screen.
STAND-BY FUNCTION SET TO OFF (FACTORY SETTING)
When the STAND-BY function is not activated (OFF), if the stove reaches the set room temperature, it will switch to the minimum power level,
modulating and displaying modulation on the screen. When the room temperature is lower than the set value, the stove will start to work
again at the set power, and work will be displayed on the screen.
STAND-BY WITH ADDITIONAL THERMOSTAT (OPTIONAL)
STAND-BY FUNCTION SET TO OFF (FACTORY SETTING)
When the STAND-BY function is not activated (OFF), if the stove reaches the room temperature set on the supplementary thermostat (open
contact), it will switch to the minimum power level and display
MODULATION
on the screen. When the room temperature is lower than the
set value on the supplementary thermostat (closed contact), the stove will start to work again at the set power, and
WORK
will be displayed
on the screen.
STAND-BY FUNCTION SET TO ON
If the STAND-BY function is activated (ON), when the room temperature set on the supplementary thermostat is reached (open contact), the
stove will switch off after a pre-set (default) delay period, and STAND - BY will be displayed on the screen.
When the room temperature is lower than the value set on the supplementary thermostat (closed contact), the stove will start to work again
at the set power, and
WORK
will be displayed on the screen
J
FOR CORRECT OPERATION, SET THE ROOM TEMPERATURE TO LOW-TA
DATE/TIME
LANGUAGE
SET DEGREES
SEE CHAPTER: COMMISSIONING SETTINGS.
J
THIS FUNCTION IS NOT RECOMMENDED FOR ENVIRONMENTS WITH SCARCE THERMAL INSULATION OR WHERE
THERE MAY BE SHARP FLUCTUATIONS IN TEMPERATURE: DOORS OR WINDOWS CONSTANTLY OPENED.