Monogram ZWL1126SR Installation Instructions Manual Download Page 5

31-7000165   Rev.1

5

Installation Instructions

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of 

an electrical short circuit, grounding reduces the risk 

of electric shock by providing an escape wire for 

the electric current. This appliance is equipped with 

a cord having a grounding wire with a grounding 

plug. The plug must be plugged into an outlet that is 

properly installed and grounded. Consult a qualified 

electrician or serviceman if the grounding instructions 

are not completely understood, or if doubt exists as to 

whether the appliance is properly grounded.

WARNING

 

Improper use of the grounding plug can result in a risk 

of electric shock. 

Do not use an extension cord. If the power supply 

cord is too short, have a qualified electrician or 

serviceman install an outlet near the appliance.

3-prong plug

Grounding pin

3-prong receptacle

Grounded receptacle box

Permanent and 

Correct Installation

DRAWER INSTALLATION

1.  Place the drawer adjacent to the wall or cabinet 

opening. Plug the power supply cord into the 

electrical outlet. 

2.  Loop (do not tie) a 36” (91 cm) string around the 

power supply cord before the drawer is slid into 

place. This will keep the cord from falling behind the 

drawer.

3.  Lift drawer into cabinet cutout using the opening as 

a grip. Carefully guide the drawer into the prepared 

opening. 

4.  As you slide the drawer back, pull the string so that 

the cord will lie on top of the drawer in a natural loop 

and avoid pinching the cord between the drawer and 

the wall.

5.  When you are sure the cord is out of the way, slide 

the drawer ¾ way back into the opening. Remove the 

string by pulling on one end of the loop.

6.  Slide the drawer all the way until the mounting flange 

is flush with the face of the cabinet. See Figure 5.

7.  Open the drawer. Using the 4 holes on the mounting 

flanges as a template, drill pilot holes the cabinet 

using a 

1/16

” drill bit. See Figure 5.

8.  Secure the drawer with the 4 screws supplied. It is 

recommended that the screws be hand tightened.

Mounting 

Flange

Figure 5

Parts Supplied

4 Screws

Summary of Contents for ZWL1126SR

Page 1: ...INSTALLATION INSTRUCTIONS Monogram Drawer Microwave MONOGRAM COM Para consultar una version en espa ol de este manual de instrucciones visite nuestro sitio de internet Monogram com...

Page 2: ...ically grounded in accordance with local codes Make sure the wall coverings and the cabinets around the Drawer Microwave can withstand the heat generated by the Drawer Microwave WARNING Never leave ch...

Page 3: ...st be solid and level Pay special attention to the floor on which the Drawer Microwave will sit The floor of the opening should be constructed of plywood strong enough to support the weight of the ove...

Page 4: ...d are secured in wood or metal so that the block is totally stable When fastening be sure that the screws do not penetrate electrical wiring or plumbing ELECTRIC OUTLET The electrical requirements are...

Page 5: ...DRAWER INSTALLATION 1 Place the drawer adjacent to the wall or cabinet opening Plug the power supply cord into the electrical outlet 2 Loop do not tie a 36 91 cm string around the power supply cord be...

Page 6: ...re to leave these installation instructions with the consumer PARTS INCLUDED Qty Description 1 Flush Mount Deflector Vent 2 Mounting Screws 1 Prepare cabinet opening as shown in Figures 6 7 8 and 9 Fi...

Page 7: ...the face of the drawer out 1 8 For the cleat must sit 1 7 16 Mounting Cleat Preferred Electrical Outlet Location Anti Tip Block 24 3 16 min 24 1 2 max flush opening width No Oven 22 mounting cleat op...

Page 8: ...tout using the opening as a grip Carefully guide the drawer into the prepared opening 6 As you slide the drawer back pull the string so that the cord will lie on top of the drawer in a natural loop an...

Page 9: ...31 7000165 Rev 1 9 Notes...

Page 10: ...31 7000165 Rev 1 09 22 GEA Printed in China...

Page 11: ...INSTRUCCIONES DE INSTALACI N Monogram Microondas de caj n ESPA OL MONOGRAM COM...

Page 12: ...nte conectado a tierra de acuerdo con los c digos locales Aseg rese de que las coberturas de la pared y los gabinetes que est n alrededor del Microondas de Caj n puedan soportar el calor generado por...

Page 13: ...nes de montaje al ras incluidas con la ventilaci n con Deflector para Montaje al Ras MEDIDAS DEL MICROONDAS DE CAJ N DE 24 Las figuras 1 y 2 contienen muchas medidas para microondas de caj n como refe...

Page 14: ...modo que el bloque quede totalmente estable Al ajustar aseg rese de que los tornillos no penetren el cableado el ctrico ni la plomer a TOMACORRIENTE EL CTRICO Los requisitos el ctricos son contar con...

Page 15: ...Instalaci n Permanente y Correcta INSTALACI N DEL CAJ N 1 Coloque el caj n de forma adyacente a la pared o a la abertura del gabinete Enchufe el cable el ctrico a un tomacorriente el ctrico 2 Enrosqu...

Page 16: ...rucciones de seguridad Aseg rese de que el consumidor cuente con estas instrucciones Ubicaci n preferente para la salida el ctrica Bloque Antivolcaduras 14 13 16 hasta la parte inferior del Bloque Ant...

Page 17: ...ontaje de 22 M n de 24 3 16 M x de 24 1 2 Ancho de la abertura al ras Repisa de 3 4 Vista Frontal Vista Frontal Mueva la ubicaci n del horno hacia abajo para mostradores largos para obtener un mejor n...

Page 18: ...ibre del gabinete usando la abertura como agarre Con cuidado guie el caj n dentro de la abertura preparada 6 A medida que deslice el caj n hacia atr s empuje la cuerda de modo que el cable quede apoya...

Page 19: ...31 7000165 Rev 1 9 Notas...

Page 20: ...31 7000165 Rev 1 09 22 GEA Printed in China...

Reviews: