4

31-7000165   Rev. 1

Installation Instructions

ANTI-TIP BLOCK

NORMAL INSTALLATION STEPS
Anti -Tip BLOCK Installation Instructions

To reduce the risk of tipping of the drawer, the 

Anti-Tip block must be properly installed located 14 

13/16-inches above the floor on which the Drawer 

Microwave will sit. The anti-tip block must be provided 

and pre-installed by the purchaser of the product or 

builder before install can be done. The anti-tip block 

is not provided by installer. See Figures 1 and 2. The 

Anti-Tip block prevents serious injury that might result 

from spilled hot liquids.

If the Drawer Microwave is ever moved to a different 

location, the Anti-Tip block must also be moved and 

installed. When installed to the wall, make sure that 

the screws completely penetrate the dry wall and are 

secured in wood or metal so that the block is totally 

stable. When fastening, be sure that the screws do 

not penetrate electrical wiring or plumbing.

ELECTRIC OUTLET

The electrical requirements are a 120 volt 60 Hz, AC 

only, 15 amp. or more protected electrical supply. It 

is recommended that a separate circuit serving only 

this appliance be provided.
The drawer is equipped with a 3-prong grounding 

plug. It must be plugged into a wall receptacle that 

is properly installed and grounded. Should you only 

have a 2-prong outlet, have a qualified electrician 

install a correct wall receptacle.

Note:

 If you have any questions about the grounding 

or electrical instructions, consult a qualified electrician 

or service person.
* Can also be installed using an electrical outlet in an 

adjacent cabinet within the area where the provided 

electrical cord can reach. Always check electrical 

codes for requirements.

3 1/2”

6”

Anti-Tip 

block

Figure 3

Preferred electrical 

outlet location*

5”

4”

Figure 4

Summary of Contents for ZWL1126SR

Page 1: ...INSTALLATION INSTRUCTIONS Monogram Drawer Microwave MONOGRAM COM Para consultar una version en espa ol de este manual de instrucciones visite nuestro sitio de internet Monogram com...

Page 2: ...ically grounded in accordance with local codes Make sure the wall coverings and the cabinets around the Drawer Microwave can withstand the heat generated by the Drawer Microwave WARNING Never leave ch...

Page 3: ...st be solid and level Pay special attention to the floor on which the Drawer Microwave will sit The floor of the opening should be constructed of plywood strong enough to support the weight of the ove...

Page 4: ...d are secured in wood or metal so that the block is totally stable When fastening be sure that the screws do not penetrate electrical wiring or plumbing ELECTRIC OUTLET The electrical requirements are...

Page 5: ...DRAWER INSTALLATION 1 Place the drawer adjacent to the wall or cabinet opening Plug the power supply cord into the electrical outlet 2 Loop do not tie a 36 91 cm string around the power supply cord be...

Page 6: ...re to leave these installation instructions with the consumer PARTS INCLUDED Qty Description 1 Flush Mount Deflector Vent 2 Mounting Screws 1 Prepare cabinet opening as shown in Figures 6 7 8 and 9 Fi...

Page 7: ...the face of the drawer out 1 8 For the cleat must sit 1 7 16 Mounting Cleat Preferred Electrical Outlet Location Anti Tip Block 24 3 16 min 24 1 2 max flush opening width No Oven 22 mounting cleat op...

Page 8: ...tout using the opening as a grip Carefully guide the drawer into the prepared opening 6 As you slide the drawer back pull the string so that the cord will lie on top of the drawer in a natural loop an...

Page 9: ...31 7000165 Rev 1 9 Notes...

Page 10: ...31 7000165 Rev 1 09 22 GEA Printed in China...

Page 11: ...INSTRUCCIONES DE INSTALACI N Monogram Microondas de caj n ESPA OL MONOGRAM COM...

Page 12: ...nte conectado a tierra de acuerdo con los c digos locales Aseg rese de que las coberturas de la pared y los gabinetes que est n alrededor del Microondas de Caj n puedan soportar el calor generado por...

Page 13: ...nes de montaje al ras incluidas con la ventilaci n con Deflector para Montaje al Ras MEDIDAS DEL MICROONDAS DE CAJ N DE 24 Las figuras 1 y 2 contienen muchas medidas para microondas de caj n como refe...

Page 14: ...modo que el bloque quede totalmente estable Al ajustar aseg rese de que los tornillos no penetren el cableado el ctrico ni la plomer a TOMACORRIENTE EL CTRICO Los requisitos el ctricos son contar con...

Page 15: ...Instalaci n Permanente y Correcta INSTALACI N DEL CAJ N 1 Coloque el caj n de forma adyacente a la pared o a la abertura del gabinete Enchufe el cable el ctrico a un tomacorriente el ctrico 2 Enrosqu...

Page 16: ...rucciones de seguridad Aseg rese de que el consumidor cuente con estas instrucciones Ubicaci n preferente para la salida el ctrica Bloque Antivolcaduras 14 13 16 hasta la parte inferior del Bloque Ant...

Page 17: ...ontaje de 22 M n de 24 3 16 M x de 24 1 2 Ancho de la abertura al ras Repisa de 3 4 Vista Frontal Vista Frontal Mueva la ubicaci n del horno hacia abajo para mostradores largos para obtener un mejor n...

Page 18: ...ibre del gabinete usando la abertura como agarre Con cuidado guie el caj n dentro de la abertura preparada 6 A medida que deslice el caj n hacia atr s empuje la cuerda de modo que el cable quede apoya...

Page 19: ...31 7000165 Rev 1 9 Notas...

Page 20: ...31 7000165 Rev 1 09 22 GEA Printed in China...

Reviews: