B
A
Design Guide
THE INSTALLATION SPACE
Water And Electrical Locations
The opening must be prepared with the electrical and
water supply located as shown.
The cutout depth must be 24"
Designed for industry standard flush installation. The
refrigerator will project forward, slightly beyond
adjacent cabinetry, depending on your installation.
Cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot
exceed the 24" installation depth shown. The top case
trim overlaps the bottom of the soffit.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install a
properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be
located on rear wall as shown.
Note:
GFI (ground fault interrupter) is not
recommended.
• Water line can enter the opening through the floor
or back wall. The water line should be 1/4" O.D.
copper tubing between the cold water line and
water connection location, long enough to extend
to the front of the refrigerator. Installation of an
easily accessible shut off valve in the water line is
recommended.
DIMENSIONS AND CLEARANCES
* Shipping height. The
refrigerator can be
adjusted to fit into a
cutout that is 83-1/2"
min. to 84-1/2" max.
height. Note that the
top case trim at the
front is 1/2" higher
and will overlap
upper cabinetry or
soffit. Use leveling
legs and wheels for
height adjustment.
Product Clearances
These refrigerators are equipped with a 2 position
door stop. The factory set 130
°
door swing can be
adjusted to 90
°
if clearance to adjacent cabinets or
walls is restricted.
3
*The finished cutout width must be:
35-1/2" for 36" models
41-1/2" for 42" models
47-1/2" for 48" models
90
°
Door Swing
130
°
Door Swing
*Finished Width
7"
5"
Electrical
Area
84 1/2" max
83 1/2" min
Finished
Opening
74" From Floor
to Bottom
of Electrical
24"
5"
5"
3 1/2"
Water Supply
3 1/2"
36" Models 12"
42" Models 18"
48" Models 20"
Allow minimum clearances for freezer door (Dimen-
sion A) and fresh food door (Dimension B) for a full
130
°
door swing and to allow for pan removal.
4" minimum clearance is required when door swing
is adjusted to 90
°
. If the 90
°
door stop position is
used, pan access is maintained, but pan removal is
restricted.
See illustrations pages 4 and 5 to determine door
swing interaction with adjacent cabinets or
countertops.
23-7/8"
Behind
Frame
C
Models
A
B
C
36"
13"
15"
20-5/8"
42"
13"
19"
26-5/8"
48"
15"
20"
28-5/8"
*84" From
Floor to
Top Frame
36", 42", or 48"
Frame to Frame
35", 41", or 47"
Case Width
*83-1/2"
at
Rear