background image

Install Screws and Bolts:

• Have someone hold the wall bracket centered in place 

with each of the holes aligned with the correct opening 
in the bracket and level with the horizontal line.

• Insert the lag screws through the bracket and into the 

stud. Tighten with a wrench.

• 

Insert the bolts into the toggle by hand until snug. 
Tighten with a wrench.

Anti-Tip Wall Bracket

Bolt

Wall Toggle

Drywall or

Steel Stud

Install Wall Toggles:

The wall toggles and bolts can be ordered as Service 
Kit #WR49X10193. Wall toggles are installed in the 
drywall and metal studs for stability. Install the wall tog-
gles as follows:
• Drill 1/2” holes at the wall markings made in the holes 

at the ends of the wall bracket.

• Hold the metal channel flat against the plastic straps 

and slide the channel through the hole.

• Gently pull back at the ends of the plastic straps to 

make the channel rest flush behind the wall.

• Hold the ends of the straps in one hand and slide the 

plastic cap along the straps until the flange of the cap 
is flush with the wall.

• Place your thumb between the plastic straps and 

bend up and down to snap the straps off at the wall.

Installation Instructions - Standard Installation

15

Plastic Straps

Metal Channel

Wood Stud

Lag Screw

Anti-Tip Wall Bracket

Cap

 STEP 4   INSTALL ANTI-TIP BRACKET (cont.)

Summary of Contents for ZIRP360NHLH

Page 1: ...Installation Instructions 36 Built In All Refrigerators and All Freezers monogram com...

Page 2: ...ck Hazard Plug into a grounded 3 prong outlet Do not remove the ground prong Do not use an adapter Immediately replace electric cords that become frayed or damaged Do not use an extension cord with th...

Page 3: ...es pi ces la port e des enfants g s de moins de 3 ans ATTENTION Risque associ la manutention d une charge lourde Ce r frig rateur est tr s lourd Pour r duire le risque de blessure lors de la manutenti...

Page 4: ...nel Routing 27 3 4 Raised Grille Panel Routing 28 3 4 Raised Door Panel Routing for Unified Installation 29 Side Panels 30 Side Cleats 30 ZUG2 Grille Panel Dimensions 30 Unified Door Panel Dimensions...

Page 5: ...Instructions for Standard Installation 5...

Page 6: ...hould be 1 4 O D copper tubing or QuickConnect kit between the cold water line and water connection location long enough to extend to the front of the unit Installation of an easily accessible shut of...

Page 7: ...r supply is recommended for each product Clearances for Multiple Single Door Installations In a side by side installation of a left and right door swing product a 1 clearance between the units is requ...

Page 8: ...panels ZUG2 For side by side installation of two trimmed models This kit provides for the installation of a unified custom grille panel to span the width of two units using a framed or overlay panel...

Page 9: ...thick must be placed between the overlay and backer panel IMPORTANT NOTE Maximum total weight for assembled door panel is 67 pounds Maximum total weight for assembled grille panel is 11 pounds Assembl...

Page 10: ...rim ZUG2 GRILLE PANEL DIMENSIONS The ZUG2 unified grille panel kit provides for the installation of a framed or overlay grille panel Depending on installation height Assemble the overlay panels in the...

Page 11: ...ew 130 DOOR SWING Scale 1 1 Frameless Cabinets The case trim overlaps cabinets at the top and sides Therefore frameless cabinets may require filler strips to prevent interference with cabinet door swi...

Page 12: ...which mates with a standard 3 prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance Have the wall outlet and circuit checked by a qualified electric...

Page 13: ...or rupture with age and cause water damage to your home SmartConnect Refrigerator Tubing Kits are available in the following lengths 2 6 m WX08X10002 8 2 4 m WX08X10006 15 4 6 m WX08X10015 25 7 6 m WX...

Page 14: ...nd must be secured to prevent the possibility of tipping forward AVERTISSEMENT Risque de basculement L appareil m nager est beaucoup plus lourd en haut et il faut le maintenir en place pour viter la p...

Page 15: ...etal studs for stability Install the wall tog gles as follows Drill 1 2 holes at the wall markings made in the holes at the ends of the wall bracket Hold the metal channel flat against the plastic str...

Page 16: ...e the power cord inside the left cavity If it has not been adjusted so the plug is easily accessible do so now Move Unit into Final Position Move appliance toward its final installed location Align th...

Page 17: ...ay for a snug fit against the unit add the washers one at a time until the pin will fit tightly into the hole Align the straight section of the pin with the hole from the underside of the rod Push the...

Page 18: ...factory installed in the 115 position Close the door Use pliers to unscrew the door stop and reinstall in the 90 degree or 130 degree position Pin Location for 90 Door Swing Pin Location for 130 Door...

Page 19: ...Secure Handle Use Front Holes to Secure Trim Right hand models shown Use the same instruc tions for left hand models IF YOU ARE INSTALLING OVERLAY PANELS GO TO STEP 10A Install Door Panel Open the do...

Page 20: ...et manufacturer will supply the custom han dle and hardware Secure the door trim using new handle side trim Discard the supplied handle Right hand models shown Use the same instruc tions for left hand...

Page 21: ...ghten one additional turn with a wrench Overtightening can cause leaks Turn on the water to check for leaks NOTE Make sure excess tubing length does not interfere with the toekick installation Freezer...

Page 22: ...Instructions for Flush Installation 22...

Page 23: ...back wall The water line should be 1 4 O D copper tubing or QuickConnect kit between the cold water line and water connection location long enough to extend to the front of the unit Installation of a...

Page 24: ...r and electrical locations for each product must be located as shown A separate 115V 60Hz 15 or 20 amp power supply is recommended for each product Note When implementing a dual installation the facto...

Page 25: ...cker panel to the overlay panel Secure the overlay panel to the backer panel with glue and screws Screws must be countersunk into the backer panel Fresh Food Door Grille 1 4 Backer Panel 69 5 16 x 33...

Page 26: ...d by cabinet maker to avoid sharp edges on the panels Edges to be treated should include the top bottom and hinge side edges IMPORTANT NOTE Maximum total weight for the assembled panels Door panel 67...

Page 27: ...ched door trim 1 4 11 32 1 4 3 4 PANEL SIDE VIEW AFTER ROUTING Front TOP DETAIL TOP CORNER VIEW SHOWING PICTURE FRAME ROUTING DETAIL BOTTOM BOTTOM Back Front Back 7 16 3 4 1 4 NOTE Routed areas should...

Page 28: ...ched grille trim 3 4 PANEL SIDE VIEW AFTER ROUTING 3 4 PANEL BOTTOM VIEW AFTER ROUTING Front TOP DETAIL TOP CORNER VIEW SHOWING PICTURE FRAME ROUTING DETAIL BOTTOM BOTTOM LEFT SIDE RIGHT SIDE DETAIL L...

Page 29: ...ROUTING 3 4 PANEL BOTTOM VIEW AFTER ROUTING Front TOP DETAIL TOP CORNER VIEW SHOWING PICTURE FRAME ROUTING DETAIL BOTTOM BOTTOM HINGE SIDE HANDLE SIDE DETAIL HINGE SIDE DETAIL HANDLE SIDE Back Front B...

Page 30: ...erlay Panel Dimensions A Width B Height 1 4 Backer Panel 69 7 8 8 7 8 0 10 Spacer Panel 68 1 2 7 5 8 1 2 Smooth Panel 74 10 7 16 IMPORTANT NOTE The maximum weight for the unified grill is 25 pounds De...

Page 31: ...unding plug which mates with a standard 3 prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance Have the wall outlet and circuit checked by a qualifi...

Page 32: ...s approved plastic tubing is supplied in the SmartConnect Refrigerator Tubing kits Do not use any other plastic water supply line because the line is under pressure at all times Other types of plastic...

Page 33: ...ints on the horizontal line Place the bottom of the wall bracket with tabs on the horizontal line Align the center notch on the bracket with the center line on the wall The anti tip wall bracket has a...

Page 34: ...Tighten with a wrench Insert the bolts into the toggle by hand until snug Tighten with a wrench Install Wall Toggles The wall toggles and bolts can be ordered as Service Kit WR49X10193 Wall toggles ar...

Page 35: ...ed above the front wheels Turn clockwise to raise or counterclockwise to lower the unit For front leveling use a 1 1 4 open end wrench Adjust height of unit to match installation cutout opening 84 1 2...

Page 36: ...36 Pin Location for 90 Door Swing Pin Location as Shipped for 115 Door Swing STEP 8 INSTALL GRILLE PANEL Raise the access panel to the stop position Loosen the screws on the side trim behind the fram...

Page 37: ...our refrigerator in place of the trim piece you just removed Place trim against the side of the refrigerator door aligned top to bottom The holes in the trim should align to the holes in the door Disc...

Page 38: ...nection Tighten the compression nut until it is just hand tight Tighten one additional turn with a wrench Overtightening can cause leaks Turn on the water to check for leaks NOTE Make sure excess tubi...

Page 39: ...Instructions for Stainless Steel Installation 39...

Page 40: ...oor or back wall The water line should be 1 4 O D copper tubing or QuickConnect kit between the cold water line and water connection location long enough to extend to the front of the unit Installatio...

Page 41: ...power supply is recommended for each product Clearances for Multiple Single Door Installations In a side by side installation of a left and right door swing product a 1 clearance between the units is...

Page 42: ...pliances These models are shipped ready for installation Optional Accessory Kits ZUGSS2 For side by side installation of two stainless steel wrapped models This kit provides a unified stainless steel...

Page 43: ...p View 130 DOOR SWING Scale 1 1 Frameless Cabinets The case trim overlaps cabinets at the top and sides Therefore frameless cabinets may require filler strips to prevent interference with cabinet door...

Page 44: ...h a standard 3 prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance Have the wall outlet and circuit checked by a qualified electrician to make sure...

Page 45: ...iances approved plastic tubing is supplied in the SmartConnect Refrigerator Tubing kits Do not use any other plastic water supply line because the line is under pressure at all times Other types of pl...

Page 46: ...on Instructions Stainless Steel Installation 46 Mark an additional hole at each end of the bracket If one of the studs is closer to the end of the bracket mark an additional hole towards the center of...

Page 47: ...and into the stud Tighten with a wrench Insert the bolts into the toggle by hand until snug Tighten with a wrench Anti Tip Wall Bracket Bolt Wall Toggle Drywall or Steel Stud Installation Instructions...

Page 48: ...wrench Adjust height of unit to match installation cutout opening 84 1 2 The unit should be level and plumb with cabinetry CAUTION The rear leveling wheels and front leveling legs are limited to a ma...

Page 49: ...ll fit tightly into the hole Align the straight section of the pin with the hole from the underside of the rod Push the pin up until it snaps into position Pliers may be used NOTE The hair pin cotter...

Page 50: ...er connection Tighten the compression nut until it is just hand tight Tighten one additional turn with a wrench Overtightening can cause leaks Turn on the water to check for leaks NOTE Make sure exces...

Page 51: ...51 Notes...

Page 52: ...afety glasses or goggles should be worn For Monogram local service in your area call 1 800 432 2737 NOTE Product improvement is a continuing endeavor at General Electric Therefore materials appearance...

Reviews: