Monogram ZEP30 Installation Instructions Manual Download Page 5

31-11062

5

Installation Instructions

2

 ELECTRICAL CONNECTIONS

ATTENTION INSTALLER

All electric wall ovens must be hard wired (direct 
wired) into an approved junction box. A plug and 
receptacle is NOT permitted on these products.

Do not shorten the flexible conduit. The conduit 
strain relief clamp must be securely attached to 
the junction box and the flexible conduit must 
be securely attached to the clamp. If the flexible 
conduit will not fit within the clamp, do not 
install the oven until a clamp of the proper size is 
obtained.

NOTE TO ELECTRICIAN: The 3 power leads supplied 
with this appliance are UL recognized for connection 
to heavier gauge household wiring. The insulation of 
these 3 leads is rated at temperatures much higher 
than the temperature rating of household wiring. 
The current carrying capacity of the conductor is 
governed by the wire gauge and the temperature 
rating of the insulation around the wire.

WARNING

 Improper connection of 

aluminum house wiring to copper leads can 
result in an electrical hazard or fire. Use only 
connectors designed for joining copper to 
aluminum and follow the manufacturer’s 
recommended procedure closely.

RECOMMENDED INSTALLATION OPTIONS

Option 1 - A junction box with a plaster ring and 90° 
strain relief, mounted to a stud behind 
the drywall.

Option 2 - Standard junction box with a straight 
strain relief.

Straight Strain Relief

Junction Box

Plaster Ring

Front of Drywall

FRONT VIEW

90° Strain Relief

Stud

BACK VIEW

Back of Drywall

Mounted 
Junction Box

Summary of Contents for ZEP30

Page 1: ...ce must be properly grounded ATTENTION INSTALLER All electric wall ovens must be hard wired direct wired into an approved junction box A plug and receptacle is NOT permitted on these products Electric...

Page 2: ...oven must be wired and fused to meet the requirements of the National Electrical Code NFPA No 70 Latest Edition available from the National Fire Protection Association Effective January 1 1996 the Na...

Page 3: ...IMPO RTAN T OBSER VEALL GOVE RNING CODE SAND ORDIA NCES Note toInstal ler Be sure toleave these instru ctions with the consu mer OWNE R Keep these instru ctions forfuture refere nce Note This applia n...

Page 4: ...a pilot hole for the 1 drywall screw Screw is installed 3 from cabinet front face and centered horizontally Attach the tether to the enclosure bottom using the provided 1 drywall screw The free end o...

Page 5: ...ousehold wiring The insulation of these 3 leads is rated at temperatures much higher than the temperature rating of household wiring The current carrying capacity of the conductor is governed by the w...

Page 6: ...lead to the branch circuit red lead and the oven black lead to the branch circuit black lead in accordance with local codes using wire nuts 5 Install proper strain relief clamp 6 Install junction box...

Page 7: ...amp 4 Install junction box cover Ground and neutral wires white Tape or Crimp Neutral wire connection Black Red Branch circuit Alternate knockout Range conduit snaps into box Junction Box Cover Instal...

Page 8: ...ng list NOTE TO ELECTRICIAN The power leads supplied with this appliance are UL recognized for connections to larger gauge household wiring The insulation of these leads is rated at temperatures much...

Page 9: ...nos electr nicos de pared deben ser cableados directamente en una caja de conexi n aprobada Un enchufe recept culo NO ES permitido en estos productos Ante cualquier duda llame a GE Appliances al 800 G...

Page 10: ...que cumplan con los requisitos del C digo El ctrico Nacional ANSI NFPA No 70 ltima edici n Usted puede obtener una copia de este c digo disponible en National Fire Protection Association Asociaci n N...

Page 11: ...VEALL GOVE RNING CODE SAND ORDIA NCES Note toInstal ler Be sure toleave these instru ctions with the consu mer OWNE R Keep these instru ctions forfuture refere nce Note This applia nce must be prope r...

Page 12: ...1 El tornillo debe ser instalado a 3 de la cara frontal del gabinete y estar centrado horizontalmente Adhiera la correa a la parte inferior del cerramiento utilizando el tornillo para pared de yeso de...

Page 13: ...ra las especificaciones de temperatura indicadas para cableado residencial La capacidad actual de conducci n del cable depende del calibre del cableado y de la clasificaci n de la temperatura del aisl...

Page 14: ...cable negro del horno al cable negro del circuito derivado de acuerdo con los c digos locales utilizando tapones de alambre 5 Instale una abrazadera adecuada de alivio de tensi n 6 Instale la tapa de...

Page 15: ...nstale la tapa de la caja de conexiones Cables a tierra y neutrales blanco Encinte o Prense Cable neutral conexi n Negro Rojo Circuito ramificado Agujero ciego alternativo El tubo de la estufa se ajus...

Page 16: ...islamiento alrededor del alambre NOTA Cableado de aluminio A WARNING UNA CONEXI N INAPROPIADA DEL CABLEADO DEL ALUMINIO RESIDENCIAL CON EL COBRE PODR A RESULTAR EN PROBLEMAS SERIOS O EN INCENDIO B Con...

Reviews: