Dishwasher Installation
15
STEP 22
POSITION INSULATION, PRE-
TOEKICK, AND SOUND
BARRIER
(on some models)
Skip this step if the sound insulation package is not
supplied with the dishwasher.
• Locate the sound insulation package and pre-toekick
packages inside the dishwasher.
• Stand the parts upright as shown.
Toekick
Panel
(On some
models.)
Insulation
Block
(On some
models.)
Dishwasher
Door
Pre-
Toekick
(On some
models.)
Sound barrier
(On some
models. Part is
already attached
to door.)
Figure AF
STEP 20
DISHWASHER WET TEST
• Turn on power supply or plug power cord into outlet, if
equipped.
• Select a cycle to run and push the
START
button.
• Ensure the door is latched. Dishwasher should start.
• Check to be sure that water enters the dishwasher. If
water does not enter the dishwasher, check to be sure
that water and power are turned on.
• Check for leaks under the dishwasher. If a leak is found,
turn off power at the breaker, and then tighten water
connections. Restore power after leak is corrected.
• Check for leaks around the door. A leak around the door
could be caused by door rubbing or hitting against
adjacent cabinets. Reposition the dishwasher if necessary.
See Step 13.
• Press and hold the
START
button for 3 seconds to cancel
the cycle. The unit will begin to drain. Check drain lines. If
leaks are found, turn off power at the breaker and correct
plumbing as necessary. Restore power after corrections
are made. See Steps 7, 9, 10 and 17.
• Open dishwasher door and make sure all of the water
has drained. If not, check that disposer plug has been
removed and/or air gap is not plugged. Also check drain
hose to be sure it is not kinked underneath or behind
dishwasher. See Step 17.
• Press
START
button once again and run dishwasher through
another cycle. Check for leaks and correct if required.
• Repeat these steps as necessary.
STEP 21 REPLACE FLOOR PROTECT
• Slide Floor Protect under dishwasher.
• Angle the rear back edge of the Floor Protect upwards to
engage mounting tabs.
• Lift front of drip tray and secure with 2 screws.
• Connect leak sensor connector to leak sensor.
WARNING:
When reinstalling the floor protect pan, make certain that
the screws have been fully secured. This will ensure that
if the unit is properly grounded, that the floor protect pan
will also be grounded.
Floor Protect
Leak sensor
Figure AE