Monogram JXBC57 Installation Instructions Manual Download Page 2

2

Before you begin—Read these instructions completely and carefully.
IMPORTANT: Save these instructions for local inspector’s use.
IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES.
Note to Installer: Be sure to leave these instructions with the Consumer.
Note to Consumer: Keep these instructions with your Owner’s Manual for future reference.

This appliance must be properly grounded. See “Power Supply”, page 10.

CAUTION

WARNING

If you received a damaged vent, you should
immediately contact your dealer or builder.

Proper installation is the responsibility of the
installer. Product failure due to improper
installation is not covered under the GE
Appliance Warranty. See the Owner’s Manual
for warranty information.

For Monogram local service in your area,
1-800-444-1845.
For Monogram service in Canada,
1-888-880-3030.
For Monogram Parts and Accessories, call
1-800-626-2002.

www.monogram.com

WARNING:
To reduce the risk of fire, electric shock, or
injury to persons, observe the following.
A. Use this unit only in the manner intended

by the manufacturer. If you have questions,
contact the manufacturer.

B. Before service or cleaning unit, switch

power off at service panel and lock the
service disconnecting means to prevent
power from being switched on accidentally.
When the service disconnecting means
cannot be locked, securely fasten a promi-
nent warning device, such as a tag, to the
service panel.

• Do not attempt to repair or replace any part

of the downdraft system unless it is specifi-
cally recommended in this book. All other
servicing should be performed by a quali-
fied technician.

• For general ventilating use only. Do not use

the exhaust hazardous or explosive materials
and vapors.

• Installation work and electrical wiring must

be done by a qualifed person(s). In accor-
dance with all applicable codes and stan-
dards including fire-rated construction.

To reduce the risk of fire and to properly
exhaust air, be sure to duct air outdoors. Do
not vent exhaust air into spaces within walls or
ceilings or into attics, crawl spaces or garages.

WARNING: TO REDUCE THE RISK OF
FIRE, USE ONLY METAL DUCTWORK.

Do not attempt to repair or replace any part
of the downdraft system unless it is specifically
recommended in this book. All other servic-
ing should be performed by a qualified
technician.

Contents

Design Information
Models Available ........................................................... 3
Accessories ..................................................................... 3
Product Dimensions ..................................................... 3
Advance Planning ..................................................... 4, 5

Installation Preparation
Cutouts for Monogram Cooktops ......................  6, 7, 8
Clearances ...................................................................... 9
Tools and Materials Required ...................................... 9
Parts Supplied ............................................................... 9
Remove Packaging ...................................................... 10
Power Supply ............................................................... 10
Venting Options .................................................... 11, 12

Ductwork
Duct Fittings ................................................................ 13

Installation
Step 1, Install Downdraft Vent ................................... 14
Step 2, Install the Ductwork ....................................... 14
Step 3, Install Raise/Lower Switch ............................ 15
Step 4, Connect Power ............................................... 16
Step 5, Install Filters, Check Operation .................... 16
Cleaning ....................................................................... 16

Accessories
JXRB57 Kit for Indoor Remote Blower Locations ... 17
JXBC57 Kit for Outdoor Remote Blower Locations 20

Summary of Contents for JXBC57

Page 1: ...ram We bring good things to life If you have questions call 800 GE CARES or visit our website at www monogram com Installation Instructions Downdraft Vent Systems 36 Wide Models ZVB36 30 Wide Models Z...

Page 2: ...evice such as a tag to the service panel Do not attempt to repair or replace any part of the downdraft system unless it is specifi cally recommended in this book All other servicing should be performe...

Page 3: ...white black and stainless steel JXRB57 optional accessory for indoor remote location of the blower motor assembly Use this kit when the blower and motor assembly will be located outside or below the c...

Page 4: ...the countertop Include the trim thickness when measuring front edge to cutout requirement By adding the trim the cooktop can be moved forward providing additional countertop depth and interior cabine...

Page 5: ...efully Gas or electrical outlets cannot be placed on the back wall of the cabinet because it may interfere with the downdraft plenum Install a standard electrical outlet within reach of the vents two...

Page 6: ...ollow as a cutting guide Measure and mark cooktop and vent overlaps to be sure there is enough flat countertop depth ZEU769 Electric Cooktops with 36 Vent Countertop Cutout Requires 22 1 2 flat counte...

Page 7: ...4 3 4 2 1 2 to Cutout ZEU30 Cooktop 1 7 8 DOWNDRAFT VENT 20 3 8 Cabinet Requires 23 inside cabinet depth See Creative Solutions install in an island or move cabinet base forward 34 Cooktop and Vent Cu...

Page 8: ...ombustible Surface 6 Min Cutout to Side Walls 3 4 22 3 4 to Back Wall 22 to Support Rail 24 3 4 2 1 2 to Cutout ZGU36 Cooktop 1 7 8 3 4 Thick Support Rail 20 1 16 DOWNDRAFT VENT 35 5 16 Cooktop Area C...

Page 9: ...30 Min 18 Min 8 Min to Wall When Installed 8 Min to Installed Wall When Electric Cooktop Models Gas Cooktop Models Tools and Materials Required Large flat blade screwdriver Jig saw Carpenter s square...

Page 10: ...t A properly grounded 3 prong receptacle should be located within reach of the vents two foot power cord Locate the receptacle inside the cabinet on the right side wall The receptacle cannot be placed...

Page 11: ...ower mounting plate can be adjusted 3 1 2 to the left or right This will help to align vent discharge to house ductwork 30 Rotation For even more flexibility the entire blower can be rotated up to 30...

Page 12: ...rge Remove and turn the blower to the right or left Reinstall the 4 nuts To locate the ductwork holes in the cabinet floor or side walls Temporarily place vent into the countertop opening Push the ven...

Page 13: ...lengths Flexible ducting If flexible metal ducting is used all the equivalent feet values in the table should be doubled The flexible metal duct should be straight and smooth and extended as much as p...

Page 14: ...nclosed space 6 PVC duct should be used when installing under a concrete slab Note Local building code must be followed for installation and in specifying approved type and schedule of PVC duct used D...

Page 15: ...side of countertop and thread the wire lead into the end of the wire box Peal film from the back of the switch trim to expose the adhesive Press trim onto the mounting bracket to set the adhesive Peal...

Page 16: ...fan OFF before lowering the vent The fan will auto matically turn off when the vent is lowered When the fan is not turned off before lower ing the vent it will automatically come on at the previously...

Page 17: ...upplied This kit provides for the installation of the blower and motor outside of the cabinet such as below the floor Use this kit for indoor remote installations only Note A 3 1 4 x 10 transtion to 6...

Page 18: ...sed parts If the appliance is relocated at a later time parts may be needed Blower Blower Mounting Plate Blower Box Hidden Screws 2 Determine Blower Location Step 1 continued Step Determine location o...

Page 19: ...ct to the 6 round inlet on the blower Tape to seal all joints Use electrical cable and connectors that conform to local codes 14 gauge min is recommended Use a length to reach between the vent and the...

Page 20: ...nd connectors sufficient length to connect the downdraft vent to the remote blower location 14 guage min is recommended must conform to local codes Tools required Pencil or chalk Measuring tape Drill...

Page 21: ...wiring or hidden utilities Check for interference with floor joists and stud walls If necessary locate the base to provide a secure installation Place a 6 round duct through the hole extending approxi...

Page 22: ...of the right side Reverse plates for a right side discharge A transition is required to connect the 3 1 4 x 10 duct to the 6 round inlet on the blower Tape to seal all joints 4 Connect Blower Wires St...

Page 23: ...w wiring Use wire nuts to secure the wire to the 3 remaining wires with plug Insert the plug into the mating plug on the vent Reinstall wire box with original screws Mount the blower onto the mounting...

Page 24: ...glasses or goggles should be worn For Monogram local service in your area call 1 800 444 1845 NOTE Product improvement is a continuing endeavor at General Electric Therefore materials appearance and...

Reviews: