Monnit ALTA Wireless Water Rope Sensor User Manual Download Page 12

State

The integer presented here is generated from a single byte of stored data. A byte consists 

of 8 bits of data that we read as Boolean (True (1)/False (0)) fields.

Using a temperature sensor as an example.
If the sensor is using factory calibrations the Calibrate Active field is set True (1) so the bit 

values are 00010000 and it is represented as 16.

If the sensor is outside the Min or Max threshold, the Aware State is set True (1) so the bit 

values are 00000010 and it is represented as 2.

If the customer has calibrated the sensor this field the Calibrate Active field is set False 

(0) AND the sensor is operating inside the Min and Max Thresholds, the bits look like 

00000000 this is represented as 0.
If the sensor is using factory calibrations and it is outside the threshold the bit values are 

00010010 and it is represented as 18 (16 + 2 because both the bit in the 16 value is set 

and the bit in the 2 value is set).
 

Note:

 These two are the only bits that typically observed outside of our testing procedures.

PAGE  10

Actions View

Notifications for a single sensor or gateway can be created, deleted, and edited by selecting 

the “Actions” tab in the sensor tab bar. 

You can toggle the Action Trigger on or off by selecting the switch under Current Action 

Triggers.
Actions are essential to the sensor because this is how alerts for the device are set for what 

to do in case of an emergency. See the 

iMonnit User Guide

 for instructions on how to create 

an action.  

Summary of Contents for ALTA Wireless Water Rope Sensor

Page 1: ...by ALTA Wireless Water Rope Sensor User Guide...

Page 2: ...STERING A WATER ROPE SENSOR IV SETTING UP THE WATER ROPE SENSOR INSTALLING BATTERIES V SENSOR OVERVIEW MENU SYSTEM SUPPORT WARRANTY INFORMATION PAGE II 2 3 3 4 4 7 II SENSOR SECURITY SENSOR COMMUNICAT...

Page 3: ...ction Boat bilge monitoring Storage monitoring Many additional applications The ALTA Wireless Water Rope Sensor detects the presence of water anywhere along the surface of the rope Sensor comes with 1...

Page 4: ...t application data Wireless devices listening on open communication protocols cannot eavesdrop on sensors Packet level encryption and verification is key to ensuring traffic isn t altered between sens...

Page 5: ...ork must come after the gateway 2 Register your Water Rope Sensor on iMonnit After you ve registered your gateway it s time to add your Water Rope Sensor to the iMonnit account 3 Install batteries in...

Page 6: ...ecurity Code from your Water Rope Sensor in the corresponding text boxes Use the camera on your smartphone to scan the QR code on your sensor and gateway If you do not have a camera on your phone or t...

Page 7: ...en iMonnit select Sensors from the navigation menu Verify that iMonnit is showing the sensor has a full battery level Pull sensor away from base Pinch press in on the sides Press sensor back into base...

Page 8: ...u are not using the sensor simply leave the button in the off position to preserve battery life If the sensor needs to be reset for any reason you can simply cycle the power by turning the switch to t...

Page 9: ...riented in the same direction pointing vertically from the sensor If the sensor is mounted flat on its back on a horizontal surface you should bend the antenna as close to the sensor housing as possib...

Page 10: ...he sensor icon denotes its status Green indicates the sensor is checking in and within user defined safe parameters Red indicates the sensor has met or exceeded a user defined threshold or triggered e...

Page 11: ...e given the sensor Date The date the message was transmitted from the sensor Value Data presented with transformations applied but without additional labels Formatted Value Data transformed and presen...

Page 12: ...nd Max Thresholds the bits look like 00000000 this is represented as 0 If the sensor is using factory calibrations and it is outside the threshold the bit values are 00010010 and it is represented as...

Page 13: ...Aware State When Water Is field allows you to set whether you want to be alerted when water is either Present Absent or when there is a State Change E Time to Rearm is the time in seconds after a tri...

Page 14: ...of such non conformance and ii the non conforming Product provid ed however if in its opinion Monnit cannot repair or replace on commercially reasonable terms it may choose to refund the purchase pric...

Page 15: ...LITY WHETHER IN CONTRACT IN TORT UNDER ANY WARRANTY IN NEGLIGENCE OR OTHERWISE SHALL NOT EXCEED THE PURCHASE PRICE PAID BY CUSTOMER FOR THE PRODUCT UNDER NO CIRCUMSTANCES SHALL MONNIT BE LIABLE FOR SP...

Page 16: ...or an experienced radio TV technician for help Warning Changes or modifications not expressly approved by Monnit could void the user s authority to operate the equipment RF Exposure WARNING To satisf...

Page 17: ...evice French Conform ment la r glementation d Industrie Canada le pr sent metteur radio peut fonctionner avec une antenne d un type et d un gain maximal ou inf rieur approuv pour l metteur par Industr...

Page 18: ...lly the instruction for its use Do not insert or remove the SIM when the product is in power saving mode Every device has to be equipped with a proper antenna with specific characteristics The antenna...

Reviews: