background image

Remote Control

NOTE: - 

The remote control should be directed towards the IR lens located on the front of the PLW-15 cabinet. For distance 

and angle limits please refer to the Set Up Guide (page 2).

Mute

1. 

Toggle between mute and normal operation. Mute can only be accessed by 
using the remote control.

Power/ Standby

2. 

Toggle between standby on/off. Standby can only be operated by the remote 
control unit. This function will not be operable when using the +12v trigger.

LFE

3. 

Toggle between LFE and 2 Channel Stereo input.

Night Mode

4. 

Toggle between night mode on/off. Night mode can only be accessed by the 
remote control.

Movies

5. 

Toggle between movie mode and FLAT/ USER mode.

Dynamic

6. 

Toggle between dynamic mode and FLAT/ USER mode.

Music

7. 

Toggle between music mode and FLAT/ USER mode.

Impact

8. 

Toggle  between  impact  mode  and  FLAT/  USER  mode.    By  pressing  the 
Music or Impact buttons whilst in the crossover or subsonic settings sections 
of the menu, the frequency will adjust in preset values.

Menu Arrow Keys

9. 

Menu  control  and  settings  adjustment.  The  menu  keys  work  in  the  same 
way as the push and turn control knob on the main control panel. Volume 
is facilitated by the left/right keys by default. Menu scroll is facilitated by the 
up/down keys.  By pressing the ‘up’ arrow key while the unit is showing the 
default screen, will enter direct into the memory recall option of the menu 
system.

Enter Key

10. 

Enter settings menu and select desired menu function for adjustment.

Escape Key

11. 

Exit set up menu. Press once for back a step and again for complete exit 
from the menu system.

monitoraudio.co.uk

8

PLW15 manual.indd   8

30/04/2008   10:59:58

Summary of Contents for PLW-15

Page 1: ...User Guide PLW 15 PLW15 manual indd 1 30 04 2008 10 59 54 ...

Page 2: ...PLW15 manual indd 2 30 04 2008 10 59 54 ...

Page 3: ...ction 5 PLW 15 Features 5 Amp Control Panel 6 7 Remote Control Functions 8 Positioning 9 Set Up 9 10 Specification 11 Trouble Shooting 12 Guarantee and Service 13 Claims under this guarantee 13 Data Protection 13 EC Declaration of Conformity 14 Owner Information 15 monitoraudio co uk 1 PLW15 manual indd 1 30 04 2008 10 59 54 ...

Page 4: ...the power cord from being walked on or pinched 10 particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer 11 Use only with the cart stand tripod bracket or table 12 specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination t...

Page 5: ...s symbol on the product or accessories indicates that they must not be disposed of with your household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources Instead it is your responsibility to dispose of your waste equipment by handing it over to a designat...

Page 6: ...eted floors All that is required is fixing into the cabinet This is achieved by simply screwing the feet fully into the 4 threaded inserts in the underside of the cabinet If your carpet has a very thick pile remove the soft polymer pad from the foot to ensure the spike goes right through the carpet onto the floor With great care turn your cabinet the right way up Place the cabinet in your desired ...

Page 7: ...ss D amplifier section delivering 1000 watts of continuous power Dynamic power limiter DSP Digital Sound Processing control of the power amplifier monitors available power and limits certain frequencies dependant on available power reserve Sealed cabinet for ultimate bass control and ease of installation Main features and settings adjustable by remote control Full DSP Control with all functions co...

Page 8: ...Amp and Control Panel 1 2 4 5 3 6 7 8 8a 9 9 11 10 monitoraudio co uk 6 PLW15 manual indd 6 30 04 2008 10 59 57 ...

Page 9: ... stand by mode waiting to receive an audio signal or a signal from the 12v trigger If it is green the unit is operational and the display on the top of the unit will also be illuminated Mains Power Switch 7 Mains rocker switch providing overall power off and on auto In the on auto mode the unit will turn on when an input signal is sensed and will turn off after a user preset delay when the signal ...

Page 10: ... USER mode Music 7 Toggle between music mode and FLAT USER mode Impact 8 Toggle between impact mode and FLAT USER mode By pressing the Music or Impact buttons whilst in the crossover or subsonic settings sections of the menu the frequency will adjust in preset values Menu Arrow Keys 9 Menu control and settings adjustment The menu keys work in the same way as the push and turn control knob on the m...

Page 11: ...ct user manual for further information As a guide the crossover should be set up in accordance with the low frequency limit of the main speakers see table on page 10 Using 2 Channel L R stereo inputs Stereo L R input may be required if using a 2 channel stereo amplifier or an older A V receiver with no LFE output Connect 2 x interconnect cables left and right from a stereo amplifier or A V process...

Page 12: ...the installer user to access the 9 band graphic equaliser settings and make adjustments 6dB gain or cut can be obtained at the pre set frequency divisions of 20Hz 25Hz 31Hz 40Hz 63Hz 80Hz 100Hz 125Hz and 160Hz These features can be used to provide a more accurate in room balance and is particularly effective at counteracting room modes or positioning anomalies A 1 3 Octave spectrum analyser or han...

Page 13: ...l Adjustment Once data has been saved the volume can be adjusted to the desired level either by the main control panel or by using the remote control Accurate level volume calibration can be done by using the auto set up procedure of the A V processor receiver See manufacturer s user guide for details Alternatively a 1 3 Octave spectrum analyser or hand held dB level meter capable of accurately me...

Page 14: ... locations Cabinet Specification Sealed Cabinet with 30mm M D F construction with critical internal bracing Sealed amplifier compartment Amplifier Classification Class D amplifier with DSP control Driver Compliment 1 x 15 C CAM sub woofer driver featuring triple suspension and 4 long throw voice coil Dimensions H x W x D 455 x 485 x 475mm 17 15 16 x 19 1 8 x 18 11 16 All dimensions excluding grill...

Page 15: ...p Has it got a signal going to it If so and the signal is turned on try adjusting the volume level of the source If it still does not turn on power up please contact your local dealer distributor or Monitor Audio immediately No sound from PLW 15 Check the correct input is selected to suit your needs Is the LED on the back red or green If it is red then the unit hasn t actually turned on See above ...

Page 16: ... packaging to the original supplier where possible or to any other authorised Monitor Audio dealer If it is not possible to return the equipment by hand then it should be sent carriage prepaid via a reputable carrier If the original packing is not available replacement packaging can be purchased from Monitor Audio If you have any difficulties complying with these requirements please contact us at ...

Page 17: ...teristics of broadcast receivers and associated equipment EN55020 12 94 A11 12 96 Electro magnetic immunity of broadcast receivers and associated equipment EN61000 3 2 04 95 A1 1998 A2 1998 Electro magnetic compatibility EMC Part 3 Limits Section 2 Limits for harmonic current emissions equipment input current up to and including 16 Ampere per phase EN6100 3 3 01 95 Electro magnetic compatibility E...

Page 18: ...il address Settings Notes Additional Notes Monitor Audio reserves the right to alter specifications without notice MEMORY 1 MEMORY 2 MEMORY 3 FEATURE Sub Sonic Filter Crossover Frequency Crossover Slope EQ Mode User EQ Settings 20 25 31 40 63 80 100 125 160 Phase Control Auto Off Mode Select Lock Setting PLW15 manual indd 16 30 04 2008 10 59 59 ...

Page 19: ...PLW15 manual indd 17 30 04 2008 10 59 59 ...

Page 20: ...d Unit 2 24 Brook Road Rayleigh Essex SS6 7XL England Tel 01268 740580 Fax 01268 740589 Email info monitoraudio co uk monitoraudio co uk Designed in the United Kingdom Version 1 PLW15 manual indd 18 30 04 2008 11 00 00 ...

Reviews: