27D7300
5
Chimney Height
Flue Opening
6'
64 sq in
8'
64 sq in
10'
64 sq in
15'
51 sq in
20'
51 sq in
30'
51sq in
Chimney Height
Flue Opening
6'
64 sq in
8'
64 sq in
10'
64 sq in
15'
51 sq in
20'
51 sq in
30'
51sq in
Chimney Height
Flue Opening
Chimney Height
Flue Opening
Chimney Height
Flue Opening
GETTING STARTED
MAKE SURE YOU HAVE RECEIVED ALL PARTS
Check your packing list to verify that all listed parts have been received. You should have the following:
BURNER - GRATE ASSEMBLY 18", 24", 30", 36"
• Burner and Grate Weldment Assembly
• Lava Rocks (x2)
• Reducer
• Glowing Embers (Rock Wool)
• Damper Clamp
• Injector
• Installation /Operating Instructions
• Vermiculite
•
3
/
8
" Aluminum Tube with
3
/
8
"
• Shield Plate
90° Elbow,
1
/
2
" to
3
/
8
" tube fi tting
18", 24", 30" OR 36" CERAMIC FIBER OR REFRACTORY LOGS
• Individual Logs
• Installation Instructions
Carefully inspect the contents for shipping damage. If any parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance.
Do not attempt to install any part of the appliance unless you
have all parts in good condition.
ITEMS REQUIRED FOR INSTALLATION
Ensure that the following items are available before proceeding with installation:
• External regulator (for propane/L.P.G. only)
• Shutoff valve
• Pipe wrench
• Piping which complies with local codes
• Drill with masonry bit (for mounting to the fl oor)
• Pipe sealant approved for use with propane/L.P.G. (Resistant to sulfur compounds)
MINIMUM FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING
MINIMUM CHIMNEY HEIGHT AND FLUE OPENING
• Handle the gas log burner assembly by the grate only. Do not pick the unit up
by the burner.
• Gloves are recommended when handling ceramic fi ber logs to prevent skin irritation
from loose fi bers. Logs are fragile — handle with care.
W
ARNING
The fi replace and gas logs function as a system. If the fi replace is not drafting properly
and spilling into the room (check with a match or a smoke stick), reposition the damper
clamp until the positive draft is obtained by opening the damper. If negative pressure
in home prevents having a positive draft, contact your dealer for assistance.
W
ARNING