26D4720
7
MINIMUM HEARTH DIMENSIONS
GENERAL INSTALLATION INFORMATION
AND
LOCATION OF FIREBOX
MCUF36
MCUF42
MCUF36
MCUF42
A
24
1
/
2
"
30
"
30
1
/
4
"
B
16"
16"
16"
16"
C
32
1
/
2
"
38
"
38
1
/
2
"
D
21"
26"
21"
26"
Figure 2 - Minimum Hearth Dimensions
LOCATION OF FIREBOX
Carefully select the best location for installation of your
vent-free fi rebox. The following factors should be taken
into consideration:
• Clearance to side wall, ceiling, woodwork and
windows. See “Clearances/Height Requirements on
page 8. Minimum clearances to combustibles
must
be maintained.
• Location must not be affected by drafts caused by
kitchen exhaust fans, ceiling fans, return air registers
for forced air furnaces / air conditioners, windows
or doors.
• Installation must provide adequate ventilation and
combustion air.
•
DO NOT INSTALL THIS FIREBOX IN A BED-
ROOM OR BATHROOM.
• Location should be out of high traffi c or windy or
drafty areas.
•
DO NOT INSTALL WHERE CURTAINS, FURNITURE, CLOTHING OR OTHER FLAMMABLE OBJECTS
ARE LESS THAN 42" FROM FRONT OF HEATER.
• Never obstruct the front opening of the vent-free fi rebox or restrict the fl ow of combustion and ventilation air.
• Minimize modifi cations to existing construction. Refer to Figure 3 below for location suggestions.
• Do not install in the vicinity where gasoline or other fl ammable liquids may be stored. The vent-free fi rebox must be
kept clear and free from these combustible materials.
Figure 3 - Location of Firebox