9
Optional Equipment
FORCED AIR KIT
(BLOTMC)
If you are installing the forced air kit, Model BLOTMC, see
the installation instructions provided with the kit for electri
-
cal wiring requirements. The firebox must be connected to
main power supply at time of firebox installation. The blower
must be installed prior to the installation of the vent free
heater. The electrical connections must be made before
the firebox is framed and enclosed in the finished walls.
WARNING!
Electrical connections should only be
performed by a qualified, licensed electrician,
main power must be off when connecting to
main electrical power supply or performing
service.
When installed, the blower must be electrically
grounded in accordance with local codes or in
the absence of local codes, with the National
Electrical Code ANSI/NFPA 70.
Figure 9.1
PANELS
Optional panels (left, right, and back) may be installed in
the
LCUF32CR-B, LCUF36-CR-B, AND LCUF42CR-B. If
panels are replaced, please refer to the firebrick liner kit
installation instructions provided with the panels for more
information.
For LCUF32CR-B, LCUF36-CR-B, AND LCUF42CR-B re
-
fractory panels are shipped installed. Once unit is in place,
remove the shipping brackets from the left and right front.
NOTE:
Brackets located on top and bottom of side panels
remain in place. See Figure 9.1.
NOTE
: When replacing side and back panels to optional
sets, the original refractory hearth brick may be used with
those sets or taken out for bare metal floor.
ACCENT LIGHT KIT (MONAL)
If you are installing the accent light kit, Model MONAL, see
the installation instructions provided with the kit for electri
-
cal wiring requirements. The firebox must be connected to
a main power supply at time of firebox installation. The
accent light kit must be installed prior to the installation
of the vent free heater. The electrical connections must
be made before the firebox is framed and enclosed in the
finished walls.
OPTIONAL DOOR KIT (DLR32B, DLR36B,
DLR42B)
If you are installing the optional door kit, see the installation
instrucions provided with the kit.
Brackets to be removed before operation.
BMGLR32
Black Magic Glass Kit for LCUF32
BMGLR36
Black Magic Glass Kit for LCUF36
BMGLR42
Black Magic Glass Kit for LCUF42
FBPREMT32
Premium Firebrick Traditional for LCUF32
FBPREMT36
Premium Firebrick Traditional for LCUF36
FBPREMT42
Premium Firebrick Traditional for LCUF42
FBPREMH32
Premium Firebrick Herringbone for LCUF32
FBPREMH36
Premium Firebrick Herringbone for LCUF36
FBPREMH42
Premium Firebrick Herringbone for LCUF42
18