CLEARANCES
AND
HEIGHT REQUIREMENTS
4.
Mantel clearances:
The canopy supplied with the unit must
be installed. If a combustible mantel is installed, it must
meet the clearance requirements as shown in
Figures 5 and
6
. However, if lower mantel height is desired, refer to page
14 for canopy options.
5. Floor clearance:
This inner chamber firebox floor must be
installed at least 5" above any combustible flooring material,
such as carpeting or asphalt tile, which is closer than 14" to the
base of the firebox.
See Figure 7.
Or
The inner chamber firebox floor may be installed nearer to the
floor if a minimum of 14" of noncombustible material such as
slate or marble is installed between the base of the firebox and
the combustible flooring.
See Figure 8.
Figure 5 - Mantel Clearances for Model GCUF32
Figure 6 - Mantel Clearances for Models
GCUF36 and GCUF42
Figure 7 - Minimum Clearance above
Combustible Flooring
Figure 8 - Minimum Clearance above Combustible
Flooring with Non-Combustible Material Installed at
Base of Fireplace
Non-Combustible
Material
5" Minimum
14" Minimum
Can Be
Less than 5"
Non-Combustible
Material