71D0532
19
ELECTRICAL WIRING
The milli-volt valve is a self-powered combination gas control
THAT DOES NOT REQUIRE 110 VAC TO
OPERATE.
CONNECTING OPTIONAL WALL SWITCH
1. Use 18 awg, two-wire cable, 15 feet maximum length.
2. At one end of the cable, connect both wires to the wall switch or thermostat. At the other end, connect one wire to
TP/TH and one wire to TH, or connect the wall switch/thermostat to the two male (0.25") terminals on the left side of
the unit. The color of the wires does not matter.
Figure 17 - Wiring Diagram
Optional Wall
Switch or Remote
Receiver
Switch
On/Off
Switch
On/Off
Switch
Wall
Switch
ODS
Pilot
Valve
TH = 3
TP = 1
TP/TH = 2
ODS
Pilot
Spade
Terminal
Label all wires prior to disconnection
when servicing controls. Wiring
errors can cause improper and
dangerous operation. Verify proper
operation after servicing.
W
ARNING
Summary of Contents for DFS32NVC
Page 43: ...71D0532 43 NOTES ...