36
NB18/NB24 Gas Log Set
Monessen • NB18/24 Gas Log Set Installation/Owner's Manual • 81D0107 • Rev E • 04/18
TOUCH SCREEN REMOTE CONTROL OPERATION - SCR MODELS
NOTE
: Due to the sensitive temperature monitoring com-
ponents in the transmitter, it is necessary to allow the
transmitter to stabilize to room temperature before accu-
rate room temperatures are displayed. If the transmitter
is activated from a severe cold condition, allow 15 min-
utes for accurate temperature readings to appear on the
LCD display.
n
Function Areas of the LCD Display
Figure 54
shows the display of the TSTSC LCD.
Information Bar
The information bar shows the room temperature, the
“sending signal” radio icon, the low battery indication icon,
the child-proof icon, and the flame icon. This area doesn’t
have touch buttons.
•
The room temperature will always be shown after
power-up. It displays the room temperature from 40
°F to 99 °F. “Lo” and “HI” will be displayed when the
room temperature is lower than 40°F or higher than
99°F, respectively.
•
The radio icon will be shown when the transmitter is
sending a signal.
•
The low battery indication icon will be shown when
the battery voltage is low.
•
The child-proof icon will be shown when the child-
proof mode is activated.
•
The flame icon indicates the current flame height -
Off, Low, Medium and High
Touch Area
The touch area contains all touch buttons to control the
transmitter. It consists of two categories: menus and ad-
justment arrows. The blue LED backlight lights up for 8
seconds when any of the touch buttons is pressed.
•
The menus include TIMER and THERMO buttons.
•
The adjustment arrows include ON/up and OFF/
down. Their default function is to turn on/off the
flame. When a button from the menu is pressed,
the ON/up and OFF/down buttons will temporarily
become adjustment controls for the selected item.
When the adjustment is done, the ON/up and OFF/
down buttons go back to flame controller again.
Logo Bar
The Logo Bar contains the brand logo: Signature Com-
mand.
n
Initialization and Set Up
Installing Batteries
Figure 55
The remote transmitter has two bat-
tery compartments, one on each end
of the transmitter.
Always change
all four (4) batteries at the same
time.
To install batteries,
1. Press down the battery door tab
and pull out to remove the battery
door.
2. Install the batteries as indicated in-
side the battery compartments.
3. Close the battery door by snapping in place.
4. When all
four
batteries are installed, the transmitter
will initialize for 5 seconds and then is ready for use.
5. The batteries should be replaced every 12 months or
when the low battery icon indicator is displayed.
Changing Temperature Unit
When batteries are installed in the transmitter,
1. All available icons on the LCD will be turned on then
be cleared.
2. The LCD will display temperature unit: °F. Use ON ∆
to toggle the units between °F and °C within the first 5
seconds.
3. The transmitter enters Manual Mode
4. The LCD displays room temperature with the chosen
unit.
FP2607
install battery
Battery
Door
Tabs
Figure 55
FP2660
TSTSC display
Information
Bar
Touch Area
Logo
Bar
Menus
Adjustment
Controls
Function Areas of the LCD Display
Figure 54
Turn appliance OFF (at the master switch) if you
are away from your house for an extended period
of time. Never leave anything on top of the surface
of the transmitter.
WARNING
Summary of Contents for BC18-R