To accommodate the various configurations, we have provided access openings in the bottom of the
unit for gas line and wall switch wires. This may not be convenient for some installations, if so you may
drill an access opening into the lower face of the unit (1" for gas line, 1/2" for the grommet).
1. Route the 3/8 inch N.P.T. black iron gas line or equivalent to the fireplace. Include a manual shut-off
valve and union in the line so the control may be disconnected for servicing. A drip leg is also
recommended in the gas supply line.
2. Install a rigid black pipe or if local codes permit a 3/8 inch flex connector and shutoff valve to the gas
line and the fireplace gas valve. Seal and tighten securely. An adapter fitting is required between the
gas valve and flex connector if used.
Do not kink flex connector
(Figure 3).
3. Check for gas leaks with a soap and water solution. D
O
NOT
USE
AN
OPEN
FLAME
.
N
OTE
: P
URGE
ALL
GAS
LINES
WITH
THE
GLASS
DOOR
OF
THE
FIREPLACE
REMOVED
. A
SSURE
THAT
A
CONTINUOUS
GAS
FLOW
IS
AT
THE
BURNER
BEFORE
INSTALLING
THE
DOOR
.
F
IREPLACE
I
NSTALLATION
8
F
IGURE
4
2 1/4
8 1/2
12
9
COMBUSTIBLE MANTLE
COMBUSTIBLE MANTLE
AND TRIM ALLOWED
AND TRIM ALLOWED
ABOVE DOTTED LINE
ABOVE DOTTED LINE
FRONT OF
FRONT OF
FIREPLACE
FIREPLACE
MEASURE FROM TOP
MEASURE FROM TOP
OF OPENING
OF OPENING
BLACK IRON PIPE
SHUT OFF VALVE
FLEXIBLE CONNECTOR
ADAPTER FITTING
F
IGURE
3
53D9019.