background image

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

WARNING:

FOR YOUR SAFETY READ BEFORE LIGHTING

FOR YOUR SAFETY READ BEFORE LIGHTING

ON

OFF

TO TURN OFF GAS TO APPLIANCE

TO TURN OFF GAS TO APPLIANCE

KNOB

KNOB

INDICATOR

INDICATOR

POSITION 

POSITION 

GAS CONTROL

GAS CONTROL

    THE FIRE DEPARTMENT.

  HAS BEEN UNDER WATER.

OR EXPLOSION.

  CONTROL SYSTEM AND ANY GAS CONTROL WHICH

  THE APPLIANCE AND REPLACE ANY PART OF THE

  QUALIFIED SERVICE TECHNICIAN TO INSPECT

  BEEN UNDER WATER. IMMEDIATELY CALL A

D. DO NOT USE THIS APPLIANCE IF ANY PART HAS

FORCE OR ATTEMPTED REPAIR MAY RESULT IN A FIRE

  TO REPAIR IT. CALL A QUALIFIED SERVICE TECHNICIAN.

  WILL NOT PUSH IN OR TURN BY HAND, DO NOT TRY

  CONTROL KNOB. NEVER USE TOOLS. IF THE KNOB

C. USE ONLY YOUR HAND TO PUSH IN OR TURN THE GAS

    IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL

5. REMOVE CONTROL ACCESS PANEL.

YOU THEN SMELL GAS, STOP! FOLLOW "B" IN THE
SAFETY INFORMATION ABOVE ON THIS LABEL.  IF YOU
DON'T SMELL GAS, GO TO NEXT STEP.

7. WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS.  IF 

6. TURN GAS CONTROL KNOB CLOCKWISE               TO "OFF".

THIS LABEL.

    INSTRUCTIONS.

  WHAT TO DO IF YOU SMELL GAS

  ON THE FLOOR.

2. SET THE ROCKER SWITCH TO "OFF".

CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT

    NEIGHBOR'S PHONE. FOLLOW THE GAS SUPPLIER'S

    IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A

    USE ANY PHONE IN YOUR BUILDING.

    DO NOT TOUCH ANY ELECTRIC SWITCH; DO NOT

    DO NOT TRY TO LIGHT ANY APPLIANCE.

  SOME GAS IS HEAVIER THAN AIR AND WILL SETTLE

  AREA FOR GAS AND NEXT TO THE FLOOR BECAUSE

B. BEFORE LIGHTING SMELL ALL AROUND THE APPLIANCE

  DO NOT TRY TO LIGHT THE PILOT BY HAND.

  DEVICE WHICH AUTOMATICALLY LIGHTS THE PILOT.

A. THIS APPLIANCE IS EQUIPPED WITH AN IGNITION

1. STOP!  READ THE SAFETY INFORMATION ABOVE ON

3. TURN OFF THE ELECTRIC POWER TO THE APPLIANCE.

4. THIS APPLIANCE IS EQUIPPED WITH AN IGNITION DEVICE

WHICH AUTOMATICALLY LIGHTS THE PILOT.

068059

068059

TO "ON".

IS TO BE PERFORMED.

9. REPLACE CONTROL ACCESS PANEL.

10. TURN ON ALL ELECTRIC POWER TO THE APPLIANCE.
11. SET THE ROCKER SWITCH TO "ON".
12. IF THE APPLIANCE WILL NOT OPERATE, FOLLOW THE

INSTRUCTIONS "TO TURN OFF GAS TO APPLIANCE" AND
CALL YOUR SERVICE TECHNICIAN OR GAS SUPPLIER.

ELECTRICAL POWER TO THE APPLIANCE IF SERVICE

IGNITION DEVICE OR OPTIONAL BLOWER, TURN OFF ALL

5. IF THE APPLIANCE IS EQUIPPED WITH AN AUTOMATIC

4. REPLACE CONTROL ACCESS PANEL.

2. REMOVE CONTROL ACCESS PANEL.
3. DEPRESS THE CONTROL KNOB INWARD SLIGHTLY

AND TURN CLOCKWISE               TO OFF. 

1. SET THE ROCKER SWITCH OR WALL SWITCH TO "OFF".

8. TURN GAS CONTROL KNOB COUNTERCLOCKWISE

DO NOT TRY TO LIGHT THE PILOT BY HAND.

O

PERATING 

I

NSTRUCTIONS

17

F

OR

 U

NITS

 

WITH

 6CEN C

ONTROLS

 I

NSTALLED

53D9019. 

Rev 

3 11/07

Summary of Contents for 624BVBYNE

Page 1: ...O NOT TRY TO LIGHT ANY APPLIANCE DO NOT TOUCH ANY ELECTRICAL SWITCH DO NOT USE ANY PHONE IN YOUR BUILDING IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE FOLLOW THE GAS SUPPLIER S INSTRUCTI...

Page 2: ...NER SUCH AS BY SNOW LEAVES OR ANY SUBSTANCE The fireplace is a decorative gas appliance Do not burn wood or other materials in this fireplace Adults and especially children should be alerted to the ha...

Page 3: ...ireplaces and have been LISTED by OMNI Test Laboratories Inc for installation and operation described in these installation and Operating Instructions All components are UL AGA CGA or CSA safety certi...

Page 4: ...PARTS DIAGRAM 3 MV MV PV PV N O C F F O 16 16 15 15 7 17 17 19 19 18 18 9 6 5 8 4 3 11 11 13 13 12 12 14 14 10 10 2 14 14 1 13 13 ON OFF PILOT TH TPTH TP 53D9019 Rev 3 11 07...

Page 5: ...Y NAT GAS CONTROL ASSY NAT GAS CONTROL ASSY E I GAS CONTROL ASSY E I TRANSITION SECTION TRANSITION SECTION RADIATION SHIELD ASSY RADIATION SHIELD ASSY HEARTH PAN EDGE LONG PNTD HEARTH PAN EDGE LONG PN...

Page 6: ...c Ignition Accessories GCKDV6E 6CEN LP Conversion Kit GCK6CLP 6CN LP Conversion Kit GCK6CN 6CLP Natural Conversion Kit 6AK Outside Air Kit 6BKB Back Refractory Look Panel 6BKS Side Refractory Look Pan...

Page 7: ...installation instructions are included with each kit PART 3 After installing the Configuration Kit Part 2 the appliance is ready for one of the following control kits 6CN Control Kit Natural Gas Stand...

Page 8: ...position the framework to accommodate the thickness of the finished wall It is not necessary to install a hearth extension with this fireplace system The junction box should be wired to the electrica...

Page 9: ...lex connector and shutoff valve to the gas line and the fireplace gas valve Seal and tighten securely An adapter fitting is required between the gas valve and flex connector if used Do not kink flex c...

Page 10: ...AIR SPACE TO SIDES AND REAR OF FIREPLACE AND REAR OF FIREPLACE FIGURE 7 7 FT 7 FT MIN APPROVED COWL FLASHING STORM COLLAR SPECIFIED BY VENT MANUFACTURER 6 TYPE B GAS VENT LISTED CEILING SUPPORT B VENT...

Page 11: ...S OF THE INSTALLATION VENTING SYSTEMS MUST BE INSTALLED AND INSPECTED ACCORDING TO THESE ISNTRUCTIONS AND LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES ACCORDING TO THE NATIONAL FUEL GAS CODE Z223 1 LA...

Page 12: ...A RECOMMENDED 3 8 SPACING FREE OF EMBER MATERIAL DIRECTLY IN FRONT OF THE FRONT BURNER PORTS OF EMBER MATERIAL DIRECTLY IN FRONT OF THE FRONT BURNER PORTS AS SHOWN FOR BEST PERFORMANCE AND EFFECT BLO...

Page 13: ...ox connect it to the switch mount the switch and cover 4 Set the wall switch to OFF 5 Light the pilot according to instructions WALL SWITCH INSTALLATION 12 COMMON COMMON LINE LINE OFF OFF PV PV ON ON...

Page 14: ...g the air shutter will cause a more blue flame but can cause flame lifting from the burner ports Propane gas models have an air shutter set at 3 16 188 inch open The same conditions as above apply for...

Page 15: ...out of the appliance paying particular attention to the pilot air shutter end of the burner air passage into and through the appliance and control 3 Vacuum or brush away all dust carbon or lint on the...

Page 16: ...ally blocked in any manner The assembly should be located above the snow line to prevent blockage by snow accumulation 3 The combustion air inlet assembly should never be mounted in a garage or storag...

Page 17: ...uct a Model 403 duct connector should be used to splice duct sections 5 If the duct is the insulated type push the insulation back from one end of the duct approximately two inches 6 Slip the exposed...

Page 18: ...SION MAY RESULT IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT NEIGHBOR S PHONE FOLLOW THE GAS SUPPLIER S IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A USE ANY PHONE IN YOU...

Page 19: ...ELECTRODE 8 DEPRESS AND HOLD GAS KNOB WHILE LIGHTING THE 8 DEPRESS AND HOLD GAS KNOB WHILE LIGHTING THE 7 TURN GAS KNOB COUNTERCLOCKWISE TO PILOT 7 TURN GAS KNOB COUNTERCLOCKWISE TO PILOT 6 FIND PILOT...

Page 20: ...other flammable vapors and liquids 14 Do follow the lighting and operation procedures given in this manual 15 Do periodically inspect the pilot and burner flame as described in the maintenance section...

Page 21: ...d Vent System 1 Blocked Venting 2 Insufficient Primary Air 1 Improper Pilot Location 2 Pilot Flame too Small 3 Burner Ports Clogged 4 Low Pressure 1 Main Gas Off 2 Defect in Gas Valve 1 Defective Auto...

Page 22: ...ve finished grade in the area of the venting including but not limited to decks and porches the following requirements shall be satisfied 1 INSTALLATION OF CARBON MONOXIDE DETECTORS At the time of ins...

Page 23: ...d in whole or in part for residential purposes c MANUFACTURER REQUIREMENTS GAS EQUIPMENT VENTING SYSTEM PROVIDED When the manu facturer of Product Approved side wall horizontally vented gas equipment...

Page 24: ...NOTES 21 53D9019 Rev 3 11 07...

Page 25: ...NOTES 22 53D9019 Rev 3 11 07...

Page 26: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING AND INSTALLATION INSTRUCTIONS TO THE APPLIANCE FOR CONSUMER USE 53D9019 Rev 3 11 07...

Reviews: