background image

38 

61D0006

MAINTENANCE AND SAFETY 

DON’Ts

1.  Donʼt allow other installations or operation considerations 

to take priority over safety considerations.

2.  Donʼt attempt to use the fireplace until the installation is 

complete.

3.  Donʼt use unlisted parts and accessories with the fireplace 

except for special flashings fabricated locally.

4.  Donʼt use damaged parts or accessories with this fire-

place.

5.  Donʼt install the fireplace in an exposed or uninsulated 

area.

6.  Donʼt install the fireplace over carpeting.
7.  Donʼt install the fireplace on a poorly constructed base 

or fail to fasten down or attach the fireplace to prevent it 

from shifting out of position.

8.  Donʼt create or allow a crack to develop between the 

metal face of the fireplace and noncombustible trim.

9.  Donʼt use power blowers or air circulation systems with 

this fireplace that are not specifically recommended by 

Monessen Hearth Systems . 

10. Donʼt  connect  accessory  air  circulation  blowers  to 

improperly fused or ungrounded electrical circuits. 

11.  Donʼt install the fireplace where flammable or explosive 

liquids or vapors are likely to be present.

12. Donʼt neglect all the considerations mentioned in this 

manual concerning clearances to combustibles, spac-

ing from obstructions and proper chimney height when 

selecting the location and installing the chimney.

13. Donʼt allow insulating materials to contact the chim-

ney.

14. Donʼt neglect to apply caulking or mastic to the required 

joints of the flashing and between the flashing roof.

15. Donʼt dry clothing or other articles near the fireplace.
16. Donʼt store or place flammable liquids, gases or pressur-

ized containers near the fireplace.

17. Donʼt neglect to instruct all responsible persons in the 

proper and safe operation of the fireplace.

18. Donʼt fail to instruct all persons, especially children and 

elderly persons, concerning the hazards of improper oper-

ation and unauthorized tampering with the fireplace.

19. Donʼt use this fireplace to burn paper, cardboard, or other 

debris.

20. Donʼt neglect to inspect and clean the chimney regu-

larly.

21. Donʼt operate the fireplace with the glass fire screen doors 

partially open. The doors should always be fully open or 

fully closed.

22. Donʼt use gasoline, kerosene, engine oil, charcoal lighter 

fluid or other flammable liquids to start or intensify a fire. 

Using these and similar materials can cause an explosion 

within the fireplace. 

23. Donʼt store fuel supply closer to the fireplace than the 

minimum spacing required for combustible materials.

24. Donʼt subject the fireplace to the intense heat of a large 

fire the first three times the fireplace is used, but build 

moderate fires to allow the materials to cure and adjust.

25. Donʼt clean the chimney with metallic devices or chemical 

cleaners.

26. Donʼt use the fireplace or chimney for venting wood or 

coal burning heaters or inserts unless approved in writing 

by Monessen Hearth Systems .

27. Donʼt put combustibles within 24 inches of the fireplace 

opening

Summary of Contents for 36" and 42" Wood Burning Fireplaces BWB400A

Page 1: ...INSTALLING SAVE THESE INSTRUCTIONS Only Unvented Gas Log Sets which have been found to comply with the Standard For Unvented Room Heaters ANSI Z21 11 2 are to be installed in this replace A hood must...

Page 2: ...or years of heating and viewing enjoyment Please take time to read this entire manual before installing or operating your replace LISTING AND CODE APPROVALS The instructions contained in this manual p...

Page 3: ...rheating Hazardous temperatures to develop on combustible materials adjacent to the replace or chimney The emission of smoke sparks or hazardous gases into the dwelling Leakage of rain water into the...

Page 4: ...from outside to enter the replace rebox When the replace is not in use the outside combustion air damper should be closed to prevent cold air from entering the rebox An outside combustion air damper i...

Page 5: ...tions of air leakage in the home Because cold air coming in may be unavoidable in some structures Monessen Hearth Systems is not responsible for heat loss or air in ltration through or around the repl...

Page 6: ...lid fuel re logs or a certi ed decorative gas appliance may be installed in the replace as described later by this instruction manual The appliance must be properly connected to a venting system PRODU...

Page 7: ...e replace in a large and open room that is centrally located in the house This will optimize heat circulation and comfort Locate replace away from frequently opened doors central heat outlets or retur...

Page 8: ...pacers 133 4 Electrical 213 4 Framing Dimension 403 4 Framing Dimension C Framing Dimension B TOP VIEW FRONT VIEW SIDE VIEW BWB400A BWB400CA BWB400IA BWBC400IA BWB500A BWBC500A BWB500IA BWBC500IA Outs...

Page 9: ...ate poor chimney draft and smoke spillage from the replace open ing into the home Use elbows to offset the chimney to avoid obstructions or to locate the chimney cap in a better location See Chimney O...

Page 10: ...estopping be used at the ceiling level for chase installation even if local codes do not require restopping Do not insulate chase with blown or ll type insulation Only allow insulation to come into co...

Page 11: ...If Necessary Metal Safety Strip Must Be Use if Unit Is Placed on Combustible Floor Metal Safety Strip Must Be Use if Unit Is Placed on Combustible Floor Figure 6 Installing Floor Protection Circulatin...

Page 12: ...xtension materials in place Screw wall ties to the face of the replace Imbed the wall ties in the mortar joints of brick stone or other non combustible materials Place metal safety strip packed with t...

Page 13: ...mney air space clearance to com bustibles 2 Place replace in the desired location Securely support and level replace Check face of the replace with a carpenter s level If replace is not plumb correct...

Page 14: ...let Height Roof Flashing Model 612 Firestop Model SF Requires 15 x15 Opening 2 min Air Space to Combustibles Top Spacer Flexible Duct Type FP 4 U Combustion Air Assembly Model AK4 Front to Back Framin...

Page 15: ...ontact with and possible damage to the chimney Install restop spacers at each ceiling level Install the proper chimney cap or chimney housing on the chimney to prevent the entry of rain and debris int...

Page 16: ...Combustibles 15 Square Opening in Joist 2 Min Clearance to Combustibles 3 Min and 2 Above Any Point Within 10 Figure 15 Residential Installation Do not install combustible materials below top spacer N...

Page 17: ...he roof and be seen on the rooftop If the chimney is to penetrate a pitched roof the hole in the roof must be rectangular instead of square and should be sized according to Table 1 INSTALLING FIRESTOP...

Page 18: ...ress down until the snap locks engage Continue to add chimney sections on top of each other until chimney is at least 6 above roof opening on all sides See Figure 19 Note As the chimney sections are i...

Page 19: ...y nails per strap Figure 20 Installing Chimney Supports Outer Pipe Flue Support Straps Fasten Securely Firestop Snap Lock Chimney Support Securely to Lower Pipes before Fastening Support Straps Chimne...

Page 20: ...ustibles SF Firestop Spacer 2 min Air Space Clearance to Combustibles Vertical Chimney Enclosure Support Straps Support Straps Note Two 2 elbows may be used when total installation height is more than...

Page 21: ...2 151 2 22 36 411 4 471 4 1 1 1 2 0 20 1 0 1 0 0 1 0 1 0 24 28 301 2 503 4 573 4 62 1 1 1 1 0 0 0 1 0 0 0 2 1 1 0 331 2 361 2 391 2 673 4 721 2 771 2 1 1 1 1 0 0 1 0 1 0 1 2 1 1 0 42 451 2 48 82 88 92...

Page 22: ...23 Chimney Center Line Figure 23 SF30 Firestop Spacer Note If the inclined portion of the chimney passes through a oor or ceiling an SF30 restop spacer should be installed to provide the restop and s...

Page 23: ...Cutting Off Top of the Flashing Flashing Figure 26 Installing Storm Collar and Chimney Cap Model SC Chimney Cap Apply Mastic Here Storm Collar Flashing 9 Place chimney cap into matching parts of the...

Page 24: ...nside the hole in the chase cover Lower inlet air telescope down into the mating pipe of the chimney until ange on the telescope section rest on ange of the chase cover overhang Note All telescoping s...

Page 25: ...when an adequate supply of air is provided by open ventilation 4 Do not take combustion air from attic space or garage space 5 Avoid extremely long runs and numerous turns in the duct leading from th...

Page 26: ...NUED Figure 31 45 Corner Installation on Slab Floor Figure 30 Installation Above Basement or Crawl Space Do not take combustion air from attic space or garage CAUTION One Wall Inside Room Inside Wall...

Page 27: ...duct clamp or screws See Figure 33 DO NOT remove the cover if the outside air will not be connected WARNING Figure 32 Attaching Outside Air Starting Collar and Insulation Ring to Left Side of Fireplac...

Page 28: ...to each duct 3 Place duck clamp over the end of each duct Tighten duct clamp down snuggly 4 Push insulation back into place and over duct clamp Figure 35 Installing Duct Connector 403 Approximately 2...

Page 29: ...of the replace and appliance to the people who will be operating them and leave all instruction manuals with the operator of the appliance If an unvented gas appliance is installed in the replace the...

Page 30: ...the gas appliance to the gas pipe according to the appli ance makers instructions 6 Pack insulation around the pipe to prevent air owing through the tube either into or out of the rebox for proper se...

Page 31: ...See Figure 38 2 Combustible mantel and or trim may be installed within shaded area in Figure 39 Use only non combustible materials below top of spacers and behind front face Note These instructions a...

Page 32: ...To nd front clearances extend a line from back corner of unit to 4 in front of replace face and 1 outside screened opening Combustible materials may be placed within shaded areas Note Do not let combu...

Page 33: ...s must be removed to gain access to the side of the replace to install junction box later Note A rectangular switch knockout is provided on the lower right hand face of the replace This replace has be...

Page 34: ...ur yard Fireplace damper must be fully opened when using a gas appliance WARNING See Gas Appliance Installation for more guidelines HOW TO BUILD A BETTER FIRE The rst three res should be of moderate s...

Page 35: ...extreme irritation for some people Use hemlock spruce juniper and other resinous woods with caution They contain moisture pockets which upon heating pop with considerable vigor Always use a re screen...

Page 36: ...utside environmental conditions such as temperature and humidity or changes in the operation of the replace can lead to rapid buildup of soot and or creosote Have a a quali ed and reputable chimney sw...

Page 37: ...heck the replace for proper adjustment and opera tion before leaving it unattended for long periods of time 13 Do inspect and clean the replace chimney regularly 14 Do keep the re screens closed when...

Page 38: ...e chim ney 14 Don t neglect to apply caulking or mastic to the required joints of the ashing and between the ashing roof 15 Don t dry clothing or other articles near the replace 16 Don t store or plac...

Page 39: ...CEMENT PARTS ARE AVAILABLE THROUGH YOUR RETAILER Item Description QTY 400 Unit 500 Unit 1 Weldment Air Door Rod 1 031867 031867 2 Firescreen Panels 2 61D0001 61D0003 3 Back Firebrick Assembly 1 61D010...

Page 40: ...for protecting oor against sparks and radiant heat 7 H2066 20 x66 hearth extension for protecting oor against sparks and radiant heat 8 AK4 4 diameter outside combustion air kit allows air from outsi...

Page 41: ...p LFSQT Square shroud termination chimney cap for chase installation use with S8 telescope pipe and VFK ashing kit Minimum chase top dimensions 26 x26 SPC Pyramid shroud termination chimney cap for ch...

Page 42: ...42 61D0006 NOTES...

Page 43: ...61D0006 43 ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING AND INSTALLATION INSTRUCTIONS TO THE CONSUMER...

Page 44: ...ct safe operation We do not warrant this replace to be in compliance with your local building code Building codes vary greatly throughout the coun try and you should determine whether your local build...