background image

  Dial Setup

High-Speed Ethernet Setup 

Plug one end of the 

phone cable into the port 

above the red bar on the 

back of the terminal base. 

Plug one end of the Ethernet 

cable into the port above the 

yellow bar on back of the 

terminal base.

Dial Setup

High-Speed Ethernet Setup

 

Plug the other end of 

the dial cable into an 

analog phone jack.  

Recommendation:

 Use a 

dedicated phone line for the 

terminal. Sharing the line 

with another device (e.g. 

a fax machine) can cause 

communication problems. 

If using a splitter, test both 

devices and note that the 

terminal and the other 

device cannot use the phone 

line at the same time.

Plug the other end of 

the Ethernet cable into 

the router/switch/hub/

internal wiring — whatever 

is applicable to the high- 

speed Internet service at 

your location. (If necessary, 

please refer to the 

Moneris IP 

Readiness Checklist

 available 

at 

moneris.com/checklist

.)

Recommendation:

 Set up 

dial backup as well (follow 

steps 1 and 2 of the 

Dial  

Setup

 instructions).

4

Plug the other end of the power cable into a power 

source. 

Recommendations:

 Always plug the power 

cable into the power source last to avoid power 

surges. Use a power bar with surge protection 

where possible. Do not use the power cable from 

your existing terminal, as it may damage your 

new terminal.

IMPORTANT: You must use the exact power 

adaptor and cables provided by Moneris Solutions 

to work with the Moneris HiSpeed 6200 terminal. 

Failure to do so may affect the operability of, or 

cause damage to the equipment.

3

 

Locate the power 

cable (which may 

be in a white box) 

and plug this end  

of the power cable 

into the middle port 

above the power icon 

on the back of the 

terminal base.

Follow these easy steps

Need Help? 1-866-319-7450

IMPORTANT: READ FIRST

 

If this is your first POS terminal 

with Moneris:

Enclosed you should fi nd your Moneris Visa 

Merchant Agreement/Moneris MasterCard 

Merchant Agreement/Moneris Debit Card and 

Terminal Agreement, Terms and Conditions. 

If this document is not enclosed, please do not 

proceed with this installation. Instead, contact 

us at 

1-866-319-7450

. Once you have obtained 

the required document, please proceed with 

your installation.

Communications setup

If you’re using dial or dial backup for IP:

If you need to dial a prefi x (e.g. 9) to connect to an outside line:

1.   Press the 

Admin 

key twice, key in

 15

 and press 

OK

.

2.   Press 

OK

 to select PREFIX, then key in the Prefi x number (e.g. 9), 

and press 

OK

.

3.   Press the 

Can/Ann

 key twice.

4.   When the screen says “TERMINAL SETUP REQUIRED,” set up your IP 

parameters. Proceed to 

If you’re using Dynamic IP 

or

 If you’re using 

Static IP

 below.

If you’re using Dynamic IP:

1.  Press the

 Admin

 key twice, key in 

08

 and press 

OK

.

2.  Press 

OK

 to select COMMS TYPE.

3.  Scroll down to ETHERNET

 

and press 

OK

.

4.  Press the 

Can/Ann

 key.

5.   When screen says “TCP HOST CONNECTION OK PRESS OK,” press 

OK

.

Note: 

If the screen says “TCP CONNECTION FAILED,” make sure the 

communication cables are properly plugged in (router/switch/

hub/internal wiring, etc.). If you are not sure, please refer to the 

Moneris IP Readiness Checklist

 available at 

moneris.com/checklist

.

6. 

 When the screen says

 “TERMINAL SETUP REQUIRED,” 

proceed

 

to

 

Initialization and logon 

in this guide

.

Note:

 If you received an optional external PINpad, refer to 

Confi guring an optional external PINpad

.

If you’re using Static IP:

 

Contact your Internet Service Provider (ISP) to gather the following 

information: terminal’s IP address, Mask ID and Gateway address.

1.  Press the 

Admin

 key twice, key in 

08

 and press 

OK

.

2.  Press 

OK

 to select COMMS TYPE.

3.  Scroll down to ETHERNET and press 

OK

.

4. Press 

OK

 to select TERMINAL SETUP.

5.  Press 

OK

 to select TERMINAL TYPE.

6. Scroll down to STATIC

 

and press

 OK

7.  Press the 

Can/Ann

 key to return to the ETHERNET SETUP menu.

8.   Scroll down to 

TERMINAL ADDR 

and press

 OK

, then key in the 

terminal’s IP address and press 

OK

. (To key in a decimal point, 

press the

 0 (zero) 

key and then the

 Admin 

key.)

9.  Scroll down to MASK ID and press 

OK

, then key in the terminal’s 

Mask ID 

and press

 OK

.

10.   Scroll down to GATEWAY and press 

OK

, then key in the 

Gateway 

Address 

and press

 OK

.

11. Press the 

Can/Ann

 key twice.

12.  When screen says “TCP HOST CONNECTION OK PRESS OK,” press 

OK

.

Note:

 If the screen says “

TCP CONNECTION FAILED

,” make sure 

the communication cables are properly plugged in (router/

switch/hub/internal wiring, etc.). If you are not sure, please 

refer to the 

Moneris IP Readiness Checklist

 available at 

moneris.com/checklist

.

13.  When the screen says “TERMINAL SETUP REQUIRED,” proceed to 

Initialization and logon

 in this guide. 

Note:

 If you received an optional external PINpad, refer to 

Confi guring 

an optional external PINpad

.

1

Note:

 If you received an Ethernet 

cable adaptor, plug the small 

end of the adaptor into the port 

above the yellow 

bar on the back of the 

terminal base, then plug one end 

of the Ethernet cable into the 

other end of the Ethernet 

cable adaptor. 

 

2

Before you get started

1.

   Please confi rm that you received:

• 

The Moneris HiSpeed 6200 terminal.

• 

The power cable (may be a two-part cable). 

• 

The dial and/or Ethernet cables.

• 

The white POS Admin card.

 If you ordered the optional external PINpad, check for it then refer 

to the confi guration instructions under 

Additional options.

 If you ordered the optional contactless reader, check for it then 

refer to the 

Setting up Your Terminal: Moneris HiSpeed 6200 with 

VIVOPay 5000 Contactless Reader 

guide included with the reader 

for setup instructions.

2.

   Make sure you have the following information (provided to you 

when Moneris contacted you to confi rm your terminal order):

   Your 13-digit 

Merchant ID

. If you currently have a nine-digit 

Merchant ID beginning with a 1, 2, or 4, simply add 0030 to the 

beginning (i.e. 123456789 becomes 0030123456789).

   Settlement type: 

System Close

 (Moneris automatically settles your 

transactions at the end of each day) or 

Merchant Close

 (you are 

responsible for settlement/close batch at the end of each day).

  Communications type: 

dial 

or

 IP/Ethernet

 with dial as backup.

  Optional features: e.g. 

loyalty cards, gift cards, Ernex Terminal ID

If any of the above required elements are missing, please call 

the General Inquiries number below.

General Inquiries: 1-866-319-7450

Tips for moving through the menus

  Press 

F1

 to say “yes” to any questions and to scroll down.

   Press 

F3

 to say “no” and to scroll up.

   Press 

OK

 to select a menu item or fi nish entering information. 

and move on to the next step.

5

Note:

 If you received an external PINpad: 

1.  Plug the PINpad cable into the port above the green bar (RS232-1) 

on the back of the 6200 terminal base.

2.  When the PINpad screen displays “<RS232>,” proceed to 

Communications setup 

 in this guide.

Wait while the terminal powers up. When the screen says 

“TERMINAL SETUP REQUIRED,” proceed to 

Communications 

setup

 in this guide. 

Summary of Contents for hispeed 6200

Page 1: ...aterials rectness accuracy reliability separately governed by the Merchant Agreement your and or your Moneris Debit the Merchant Agreements nt s responsibility to ensure followed at all times Please r...

Page 2: ...rdered the optional external PINpad check for it then refer to the configuration instructions under Additional options If you ordered the optional contactless reader check for it then refer to the Set...

Page 3: ...ou mu adaptor and cables to work with the Mo Failure to do so may cause damage to th 3 Locate the power cable which may be in a white box and plug this end of the power cable into the middle port abov...

Page 4: ...2 Press OK to select COMMS 3 Scroll down to ETHERNET 4 Press the Can Ann key 5 When screen says TCP HO Note If the screen says TC communication cables are hub internal wiring etc If Moneris IP Readin...

Page 5: ...optional external PINpad If you re using Static IP Contact your Internet Service Provider ISP to gather the following information terminal s IP address Mask ID and Gateway address 1 Press the Admin k...

Page 6: ...and press OK If your merchant number begins with Key in 00301 1 888 699 7299 00302 1 888 358 8602 00304 1 888 332 8433 4 The terminal will now communicate with the Moneris host Over the next few momen...

Page 7: ...s the Can Ann key to return to the READY screen Note To change the default values for Tip Entry gift cards refer to the HiSpeed 6200 Operating Manual Visit moneris com 6200 to download a copy Moneris...

Page 8: ...in terms of their correctness accuracy reliability or otherwise Your credit and or debit card processing is separately governed by the Terms and Conditions of your MonerisVISA Merchant Agreement your...

Reviews: