Installation and Operating Instructions Kalla
Installation of external control and sensor
Included in the package:
Controller
The most suitable location for installing the wall sensor is on
the wall where the benches are mounted. Its distance to the
ventilation duct should be at least 50 mm.
Drill a 3.5 mm hole in the wall panel and route the wire under
the panel to the heater. Ensure that approximately 10 mm of the
sensor remains visible. If needed, the sensor can be attached to
the hole with a small drop of silicone adhesive. The length of the
sensor cable is 6 m. Cut the excess wire and connect the other end
to the heater.
Ensure that a minimum of 7 mm of the end of the
wire is stripped to ensure a proper contact.
The wall mounting plate is either mounted to the wall using three
screws or affixed to the bottom of the mounting box. The mounting
plate is covered first with a cover plate and finally with the control
panel. The length of the sensor cable is 8 m. Cut the excess wire
and connect the other end to the heater. When installing the
control panel, make sure that the cables do not become detached
or bend.
NOTE!
Remove the plastic protection film of the control panel before
using the heater.
Sensor