Installation and Operating Instructions Balance
10
The time switch (4+8 h) operates as the heater’s main switch. After the desired time the time switch
automatically turns the power off from the heater. If you wish the heater to warm up after a set time,
you can set the timer to start the warm-up after 1-8 hours. The maximum warm-up time is 4 hours.
example:
If you wish to go to the sauna as soon as possible, set the time switch between 1 and 4. The heater
switches on immediately and begins to warm up. The desired temperature can be set by turning the
thermostat.
If you wish to go to the sauna in three hours, set the timer to 2 on the time switch 1-8. The timer starts
and the power will be turned on and the heater will start to warm up after two hours.
When power has been turned on, the heater will remain on for up to 4 hours. After this power will be
turned off automatically. If desired, power can be switched off earlier by turning the time switch to zero (0).
always make sure that the time switch has turned power off after the set time period!
9. The operation of the clock timer and thermostat of the C-type
Time switch
Overheat protectors
reset switch
Thermostat
Additional connection options
Wiring a signal light outside the sauna room:
The H07RN-F cable should be used as connection cable and its cross-sectional area should be the
same as that of the connecting cable
control of electric heating with the heater:
The electric heating control cable should be brought directly to the heater’s junction box and then
further to the heater’s terminal block with a rubber cable as strong as the connecting cable.