background image

Replace the battery.

Ensure that the replacement battery is plugged 

into the PCB 

fi

 rmly. Carefully place the right half 

(1055-4241-111) onto the left (1055-4242-111). 

Align the display board [F], battery [G], and main 

PCB [H] into the slots provided in the case. Align 

the display and battery 

fi

 rst, then from the front 

of the unit, guide the PC Board into the retaining 

slots with a wooden stick. Ensure the trigger wires 

[I] and DC Jack [J] are properly in place.
Fasten both halves using two 2” self tapping 

screws [D] (1053-3328-001) through the body of 

the right half. Do not over tighten screws.
Gently pry apart case halves at the base of the 

handle and insert tee nut [K] (1053-0270-001) 

into slot in left handle.
Slip knotted end of wrist strap [L] (3051-2000-

015) over left half handle standoff and through 

slot provided.
Carefully press case handles together, ensuring 

the wrist strap 

fi

 ts into the notch provided and no 

wires are pinched between the case halves.
Re-attach the re

fl

 ector housing. 

Do not over tighten screws [C], [D1], [D2].

[F]

[D1]

[D2]

[D1]

[G]

[H]

[I]

[J]

[K]

[L]

Top half of the 

Battery Holder sits 

in the right side case. 
Note the position of 

the cradle guides

Placing the left side of the case 

on a roll of tape or other lift 

will prevent the speed knob 

from pushing the PCB out of 

the retaining slots when 

aligning all.

Monarch Instrument © 2018 

Nova-Strobe Battery Replacement 8/2018 v3.0