Replace the battery.
Ensure that the replacement battery is plugged
into the PCB
fi
rmly. Carefully place the right half
(1055-4241-111) onto the left (1055-4242-111).
Align the display board [F], battery [G], and main
PCB [H] into the slots provided in the case. Align
the display and battery
fi
rst, then from the front
of the unit, guide the PC Board into the retaining
slots with a wooden stick. Ensure the trigger wires
[I] and DC Jack [J] are properly in place.
Fasten both halves using two 2” self tapping
screws [D] (1053-3328-001) through the body of
the right half. Do not over tighten screws.
Gently pry apart case halves at the base of the
handle and insert tee nut [K] (1053-0270-001)
into slot in left handle.
Slip knotted end of wrist strap [L] (3051-2000-
015) over left half handle standoff and through
slot provided.
Carefully press case handles together, ensuring
the wrist strap
fi
ts into the notch provided and no
wires are pinched between the case halves.
Re-attach the re
fl
ector housing.
Do not over tighten screws [C], [D1], [D2].
[F]
[D1]
[D2]
[D1]
[G]
[H]
[I]
[J]
[K]
[L]
Top half of the
Battery Holder sits
in the right side case.
Note the position of
the cradle guides
Placing the left side of the case
on a roll of tape or other lift
will prevent the speed knob
from pushing the PCB out of
the retaining slots when
aligning all.
Monarch Instrument © 2018
Nova-Strobe Battery Replacement 8/2018 v3.0