connecting an inductive load (e. g. relay), the pro-
tective diode D1 must be connected in parallel to it in
reverse direction!

4.3.3 Power supply

As a power supply a regulated power supply unit with
an output voltage between 7 V

and 30 V

is re-

quired, e. g. PS-362ST by MONACOR.
1) In case of power supply units with variable output

voltage adjust them between 7 V and 30 V.

2) Connect the power supply unit:

the positive pole to terminal 2 “DC +7 – 30V” and
the negative pole to terminal 1 “GND”.

3) Only after all other connections have been made,

connect the power supply unit to a mains socket
(230 V~/50 Hz). After applying the operating volt-
age the receiver is switched on, and the internal
power LED (7) lights up.

After the operation disconnect the power supply

unit from the mains socket.

4.4 Making the Adjustments

4.4.1 Channel selection

The wireless transmission is made in the 2.4 GHz
range divided by the manufacturer into five channels
at a distance of 14 MHz. As a maximum three chan-
nels can be used at the same time (channels 1, 3, and
5) because two channels directly next to each other
interfere with each other. The following channel se-
lection is recommended:
in case of two transmitters:

channels 1 and 5

in case of three transmitters: channels 1, 3, and 5

Adjust the receiver with the rotary switch (8) to the
channel of the transmitter:

4.4.2 Matching the video level

The video output level at terminal 8 “Video” is ad-
justed to 1 Vpp according to standard. However, if the
picture on the screen appears too bright or too dark,
match the level with the control “Videopegel” (6)
accordingly. For this purpose pierce the circle of the
label, and make the adjustment with a small screw
driver.

5

Specifications

Receiving frequency:  . . . . channel 1    2.4145 GHz

channel 2    2.4285 GHz
channel 3    2.4425 GHz
channel 4    2.4565 GHz
channel 5    2.4705 GHz

Antenna:  . . . . . . . . . . . . . internal, with 8 dB gain

Range

in the open:  . . . . . . . . . up to 1200 m
in buildings:  . . . . . . . . . 70 – 125 m

Video

output level:  . . . . . . . . . 1 Vpp/75

±0.5 V adjustable

bandwidth:  . . . . . . . . . . 30 Hz – 5 MHz

Audio (2 audio channels)

output level:  . . . . . . . . . 500 mV/1 k

bandwidth:  . . . . . . . . . . 15 Hz – 16 kHz

Output control channel:  . . open collector, 

max. 15 V/80 mA

Power supply:  . . . . . . . . . 7 – 30 V /150 mA at 12 V

Protective class of housing: IP 54

Ambient temperature:  . . . -10 °C to +55 °C

Dimensions:  . . . . . . . . . . . 180 x 135 x 70 mm

Weight: . . . . . . . . . . . . . . . 400 g

According to the manufacturer.
Subject to change.

9

ENGLISH

Position

Channel

0 or 1

1

2

2

3

3

4

4

5

5

6 to F

1

Summary of Contents for Security 19.2850

Page 1: ...TAGEANLEITUNG MOUNTING INSTRUCTIONS NOTICE D UTILISATION 2 4 GHz FUNKSYSTEM EMPF NGER F R DEN AUSSENBEREICH 2 4 GHz WIRELESS TRANSMISSION SYSTEM RECEIVER FOR OUTSIDE APPLICATIONS AV 3030R Best Nr 19 2...

Page 2: ......

Page 3: ...our unit by MONACOR With these operating instructions you will be able to get to know all functions of the unit By following these instructions false operations will be avoided and possible dam age to...

Page 4: ...4...

Page 5: ...GND 4 Audio B 3 GND 2 DC 7 30V 1 GND 1 2 3 4 1 AV 3030R 10 Sw Ch 9 GND max 80mA 0 15V D1 R1 Unterseite Bottom side Partie inf rieure Innenteil Inside part Partie int rieure Anschlu des Schaltkanals Co...

Page 6: ...lichen Gegebenheiten und dem verwendeten Sen der ab Im freien Gel nde kann sie bis zu 1200 m betragen in Geb uden je nach Beschaffenheit der W nde 70 125 m 4 Inbetriebnahme 4 1 Platzierung von Sender...

Page 7: ...pannung ist der Empf nger eingeschaltet und die interne Betriebsanzeige 7 leuchtet Nach dem Betrieb das Netzger t wieder aus der Steckdose ziehen 4 4 Einstellungen vornehmen 4 4 1 Kanalwahl Die Funk b...

Page 8: ...inal mounting a test run is recommended as the transmission quality can substantially be changed by displacing the units by only a few centimetres 4 2 Mounting 1 To be able to connect the receiver aft...

Page 9: ...ther interfere with each other The following channel se lection is recommended in case of two transmitters channels 1 and 5 in case of three transmitters channels 1 3 and 5 Adjust the receiver with th...

Page 10: ...selon la condition des murs 4 Fonctionnement 4 1 Installation de l metteur et du r cepteur L exp rience d montre que pour une r ception opti male une installation une hauteur entre 1 5 m et 2 m au moi...

Page 11: ...r glages 4 4 1 S lection du canal La transmission sans fil s effectue dans la plage 2 4 GHz divis e par le fabricant en 5 canaux avec une distance de 14 MHz On peut utiliser simultan ment 3 canaux ca...

Page 12: ...Copyright by MONACOR International GmbH Co KG Bremen Germany All rights reserved www monacor com 11 01 01...

Reviews: