Heat Pump Operation:
The living room comfort control operates the roof air conditioners.
• Select the desired Zone by pressing the
ZONE
button.
• Press the
MODE
button repeatedly until
HEAT PUMP
is displayed.
• Set desired fan speed by pressing the
FAN
button.
• Set desired heating temperature by pressing the
UP
or
DOWN
buttons.
The furnace and its related components are 12 Volt DC operated, using
LP-Gas as the fuel source. Electronic circuitry (automatic ignition) is used to
ignite the burner. The furnace uses outside air for the burner combustion and
exhaust is expelled through the outside vent. Inside air is drawn into the furnace
and blown across the internal heat exchanger. Heated air is then discharged
through ducted hoses which can be run throughout the motorhome.
WARNING: IF YOU SMELL GAS extinguish all open flames
and turn off the main gas supply. Liquid propane is a highly
volatile, extremely dangerous gas. It can explode or ignite,
which may result in property damage, injury or death.
Propane is “heavy” and can “float” on the floor or “hide” in
corners. Open all windows and doors. Do not touch electrical
switches. They may spark, which can ignite. Keep all open
flames, spark producing devices and smoking material out of
the area. Contact a qualified service center to have the prob-
lem correctly diagnosed and repaired before resuming opera-
tion.
CAUTION: Do not store any items or materials in the furnace
area. Restricted air flow may hamper furnace operation
leading to failure and/or fire hazard.
The furnace operates in the following manner: The wall thermostat sends a
signal to the front roof air conditioner circuit board, which closes a relay.
Closing a relay sends an electrical signal to the furnace to begin the ignition
cycle. There is a small time delay before the blower motor begins. Once the
blower motor attains a predetermined speed it will close the sail switch. The
sail switch, which is now closed, sends the electrical signal through a high
temperature protection switch, then to the automatic ignition circuit board.
After the thermostat is satisfied, the gas valve closes and extinguishes the burner.
The blower motor stops approximately two or three minutes after cool down.
The furnace will operate when the following conditions have been met:
1. The LP-Gas valve on the LP tank is open and the LP-Gas valve at the
furnace is on.
2. The house batteries in the motorhome are fully charged.
Appliances
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
DIPLOMAT
4 • 1 2 1
Operation
FURNACE
Summary of Contents for 2002 Diplomat
Page 12: ......
Page 24: ......
Page 60: ...Driving Safety DIPLOMAT 2 6 0 VIEWS FRONT VIEWS REAR...
Page 68: ...Driving Safety DIPLOMAT 2 6 8 NOTES...
Page 70: ......
Page 98: ......
Page 130: ...Appliances DIPLOMAT 4 1 3 0 NOTES...
Page 132: ......
Page 168: ......
Page 186: ...Water Systems DIPLOMAT 6 1 8 6 NOTES...
Page 188: ......
Page 200: ...LP Gas Systems DIPLOMAT 7 2 0 0 NOTES...
Page 202: ......
Page 232: ...Electrical Systems House DIPLOMAT 8 2 3 2 NOTES...
Page 234: ......
Page 262: ...Electrical Systems Chassis DIPLOMAT 9 2 6 2 NOTES...
Page 264: ......
Page 313: ...GLOSSARY OF TERMS 315 INDEX 319 SURVEY 323...
Page 314: ......
Page 324: ...FOLD CUT ALONG DOTTED LINE FOLD...