Installing Fiber Adapter Plates (Fig. 6) 

  Up to four Fiber adapter plates can be installed in the enclosure. 

   Adapter plates utilize corner retention push pins when pulled upon two corner fasteners. 

  Position the Fiber adapter plate in the appropriate location within the enclosure and push 

the two corner fasteners gently back until they will go no further. 

 
 
 

 
 
 

 
 

Installing Mod Link Cassettes 

  Up to four Mod link cassettes may be installed in the enclosure. 

  Mod link cassettes utilize corner retention push pins which when pulled upon open two 

corner fasteners. 

  Position the Mod link cassettes in the appropriate location within the enclosure and push 

the two corner fasteners gently back until they will go no further 

  Splice Cassette installation also will follow the same procedure as Mod Link Cassette. 

 
 

 

 

Fig. 6

 

 

WARNING:  

Dust caps should be left intact on all adapters not in use. 

Never look into an open adapter as laser light may be present and is invisible. Serious eye 
damage is possible. 

Summary of Contents for RFR-00082

Page 1: ...EP THIS GUIDE FOR FUTURE REFERENCE RFR 00082 1U 24 PORT CONFIGURABLE FIBER SLIDING DRAWER DIRECTION BELOW APPLY SPECIFICALLY TO THE ENCLOSURE Installing adjustable mounting angles Fig 1 The mounting brackets can be installed in one of two positions which effects Depth of the enclosure is installed in the rack or cabinet Use M4 Philips pan head screws to attach mounting brackets to the enclosure Fi...

Page 2: ...ls Fig 3 Spools are secured using kep nuts Note Do not install slack management Spools for Mod link MTP cable and Modular Splice Cassette installations Fig 3 Back Cable Entry Retention Fig 4 Cables can enter in either the left or right back side of the enclosure Secure cables with Velcro strips or cable ties to the strain relief tie off feature Fig 4 OPEN CLOSE ...

Page 3: ...6 of slack b w the cable entry point and the point where the cable begins to spool around the slack management spools or Velcro straps Do not install slack management spools when using Mod link MTP assemblies Mark cable jacket 18 back from MTP connector with a marker Secure cable with Velcro or wire ties at the point of entry Route the slack inside the enclosure around the spool Group cables by si...

Page 4: ...hey will go no further o Installing Mod Link Cassettes Up to four Mod link cassettes may be installed in the enclosure Mod link cassettes utilize corner retention push pins which when pulled upon open two corner fasteners Position the Mod link cassettes in the appropriate location within the enclosure and push the two corner fasteners gently back until they will go no further Splice Cassette insta...

Reviews: