2.1
Set-Up
Caution: Always disconnect the air pressure until the system is ready to operate.
The principal mechanical parts of the 63816-1700 Dieless Crimping Tool are illustrated in Section 5 Assembly
Drawings.
Air Supply Hook-Up
1.
Select the 1/4 NPT threaded fittings that are compatible
with your air supply.
2.
Next install the fittings to the filter, regulator, gauge unit.
The air supply should be 20 CFM (550 L/M) and 100 PSI
(6.9 Bars) to obtain the rated hydraulic output. Air pressure
should be regulated to a maximum of 125 PSI (8.6 Bars).
See Figure 2-1.
Hydraulic Connections and Bench Mounting
1.
Remove the dust cap from the hose where it attaches to
the crimp head.
2.
Connect the quick connect coupler onto the cylinder inlet
on the crimp head. See figure 2-1.
Figure 2-1
AIR SUPPLY
CUSTOMER
SUPPLIED
FILTER, REGULATOR, AND GAUGE
THE LUBRICATOR IS OPTIONAL
AIR HOSE
DIELESS
CRIMPING HEAD
HYDRAULIC
HOSE
QUICK
CONNECT
COUPLER
POWER UNIT
WORK BENCH
SWIVEL BASE
Figure 2-2
WASHER (4)
HEX NUT (4)
M8 or 5/16-18
FLAT HEAD