background image

Extractor Tool for Crimp Terminals 

Doc No: ATS-638132700 

Release Date: 11-07-07 

UNCONTROLLED COPY

 

Page 7 of 7 

Revision M 

Revision Date: 09-01-09 

Figure 17 

HOUSING 

INSERT EXTRACTOR 

TOOL INTO SLOT 

TERMINAL 

WIRE 

EXTRACTOR 

TOOL 

TERMINAL LOCKING 

TAB PUSHED UP 

TERMINAL 

Figure 18 

 

For 94518 Terminal Series: 

 
1.

 

Push the wire of the crimped terminal to be removed forward into the connector housing before using the 
Extractor Tool. 

2.

 

Insert the Extractor Tool into the slot below the terminal, seated in the connector housing and slide it 
forward until it stops.  See Figure 17. 

3.

 

Pull the wire and terminal back through the Connector slot in the arrow direction as shown.  See Figure 
18. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

CAUTION

:  Molex specifications are valid only when used with Molex terminals, applicators and tooling. 

 
Molex does not offer repair parts for Extraction Tools due to the inexpensive nature of the tool. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Americas Headquarters 

Lisle, Illinois 60532 U.S.A. 
1-800-78MOLEX 
[email protected] 
 

Far East North Headquarters 

Yamato, Kanagawa, Japan 
81-462-65-2324 
[email protected] 
 

Far East South Headquarters 

Jurong, Singapore 
65-6-268-6868 
[email protected] 
 

European Headquarters 

Munich, Germany 
49-89-413092-0 
[email protected] 
 

Corporate Headquarters 

2222 Wellington Ct. 
Lisle, IL 60532 U.S.A. 
630-969-4550 
Fax: 630-969-1352 

Visit our Web site at http://www.molex.com 

 

Summary of Contents for 63813-2700

Page 1: ...roof Crimp Terminal 20 22 AWG 52213 50148 8000 50148 8100 50351 2 50mm 098 Pitch Mini Lock Wire to Board and Wire to Wire Crimp Terminal 51102 51163 and 51103 50351 8000 50351 5100 50539 3 96mm 156 Pitch Wire to Board Crimp Terminal 51144 50539 8000 50539 8100 50539 9001 56086 2 00mm 079 Pitch Crimp Terminal 51227 56086 8000 56086 8100 56134 8000 56134 8100 56134 2 00mm 079 Pitch Crimp Terminal 51...

Page 2: ...in Figure 6 Make sure the straight edge of the extractor tool is up against the housing lock 3 Gently lift up on the housing tab and push the terminal back through the connector slot and pull the terminated wire out in the arrow direction See Figure 1 For 35465 Terminal Series 1 Push the terminal and the wire forward in the arrow direction before using this Tool 2 Insert the Tool into the slot abo...

Page 3: ...5725 Terminal Series 1 Push the terminal and the wire forward into the housing before using this Tool 2 Insert the Tool into the area above the terminal contact and below the protruding tip of the terminal locking tang in the housing 3 Lift the locking tab upward until it is above the contact of the terminal This will free the terminal from the housing 4 Pull the crimped wire and terminal back thr...

Page 4: ...e 6 Insert the Extractor Tool into the slot on the side of the connector housing 2 Depress the terminal locking tang beams and push the terminal back through the connector slot Pull the terminated wire out in the arrow direction See Figure 7 For 50147 and 50148 Terminal Series 1 For terminal series 50147 push the terminal forward in the arrow direction before using the Extractor Tool 2 Insert the ...

Page 5: ...elease the terminal from the housing For 501930 Terminal Series 1 Line up the terminal to be removed in the connector assembly with the tip of the Extractor Tool Insert and slide the Extractor Tool into the slot on the side of the connector housing as shown Positioning it under the housing lock as shown in Figure 10 2 Slide the Extractor Tool in the direction shown lifting up the housing lock Whil...

Page 6: ...f the arrow See Figure 13 For 56086 56134 56187 57964 and 59370 Terminal Series 1 Push the terminal forward in the arrow direction before using the Extractor Tool Insert the Extractor Tool into the slot on the side of the connector housing as shown in Figure 14 2 While depressing the housing lock push the terminal back through the connector slot and pull the terminated wire out in the arrow direct...

Page 7: ...ure 17 3 Pull the wire and terminal back through the Connector slot in the arrow direction as shown See Figure 18 CAUTION Molex specifications are valid only when used with Molex terminals applicators and tooling Molex does not offer repair parts for Extraction Tools due to the inexpensive nature of the tool Americas Headquarters Lisle Illinois 60532 U S A 1 800 78MOLEX amerinfo molex com Far East...

Reviews: