Hand Crimp Tool for MOX 0.635mm (.025") Receptacle Crimp Terminals
Doc No: ATS-6381193HM
Release Date: 08-24-07
UNCONTROLLED COPY
Page 4 of 7
Revision: B
Revision Date: 08-03-10
INCORRECT
Figure 5
CORRECT
INCORRECT
Terminal Locator Replacement/Change Over
This section describes the procedure for changing locators.
Removal
1.
With the tool in the open position, pivot the terminal locator outward.
2.
Remove the M4 BHCS. See Figure 4.
Installation
1.
Place the proper locator, (See Chart on page 2), on the hand tool.
Install the M4 BHCS. See Figure 4.
2.
Tighten the screw enough to hold the locator. Make sure the
locator can still float freely with hand pressure.
3.
Insert the proper terminal fully into the correct profile slot until the terminal is fully seated and stops. Then
gently pivot the locator closed.
4.
With hand pressure, slowly slide the locator to the correct position. See Figure 5.
5.
Gently pivot the locator open without disturbing the location.
6.
Hold the locator firmly in place and slowly tighten the M4 BHCS.
Maintenance
It is recommended that each operator of the tool be made aware of, and responsible for, the following
maintenance steps:
1.
Remove dust, moisture, and other contaminants with a clean brush, or soft, lint free cloth.
2.
Do not use any abrasive materials that could damage the tool.
3.
Make certain all pins; pivot points and bearing surfaces are protected with a thin coat of high quality machine
oil. Do not oil excessively. The tool was engineered for durability but like any other equipment it needs
cleaning and lubrication for a maximum service life of trouble free crimping. Light oil (such as 30 weight
automotive oil) used at the oil points, every 5,000 crimps or 3 months, will significantly enhance the tool life.
4.
Wipe excess oil from hand tool, particularly from crimping area. Oil transferred from the crimping area onto
certain terminations may affect the electrical characteristics of an application.
5.
When tool is not in use, keep the handles closed to prevent objects from becoming lodged in the crimping dies,
and store the tool in a clean, dry area.
Miscrimps or Jams
Should this tool ever become stuck or jammed in a partially closed position,
Do Not
force the handles
open or
closed
. The tool will open easily by lifting the ratchet release lever. See Figure 9.
M4 BHCS
PIVOT LOCATOR
Figure 4