RAST 5.0 Semi-Automatic Terminator Machine
Doc: No: ATS-623006100
Release Date: 04-28-09
UNCONTROLLED COPY
Page 24 of 65
Revision: A
Revision Date: 04-28-09
This screen is displayed when the NEXT button is
pressed on Manual Screen #1.
Hsg Feed Button:
This button allows manual
operation of the Housing Feed Cylinder. Pressing
the button once will allow the cylinder to move
forward, pressing it again will return the cylinder to
the back position. The text on the button will change
between
FORWARD
and
BACK
as the button is
pressed. The cylinder can move
FORWARD
only
when the Mask tooling is up.
Mask Tooling Button:
This button allows manual
operation of the Mask Tooling Cylinder. Pressing
the button once will allow the cylinder to move up,
pressing it again will return the cylinder to the down
position. The text on the button will change between
UP
and
DOWN
as the button is pressed.
Termination Button:
This button allows manual
operation of the Termination Cylinder. Pressing the
button once will allow the cylinder to move down,
pressing it again will return the cylinder to the up
position. The text on the button will change between
DOWN
and
UP
as the button is pressed. The
cylinder can move
Down
only when the Housing
Feed is back.
PREV:
Changes the screen to Manual Screen #1.
SET UP:
Selects Set Up mode and changes the
screen to the Set Up #1 [Screen 40].
MAIN:
Select Automatic mode and changes the
screen to Ready to Run [Screen 2].
CLEAR:
Clears any faults.
Screen 40
Set Up #1 Screen
This screen is displayed when the SET UP button is
pressed on the Manual Screens or PREV has been
selected from the Set Up #2 Screen.
CIRCUIT SIZE:
This displays the current circuit size
of the connectors being processed.
ENTER CIRCUIT SIZE:
This button allows the
circuit size of the connector to be entered. When
the button is pressed a pop-up screen [Screen
65001] will appear. When the ENTER button on the
pop-up Screen is pressed, the circuit size will be
displayed on the button. Only values between 2 nd
12 will be accepted by the display.
Parts Made:
Displays how many assemblies have
been made in the current batch.
NEXT:
Changes the screen to the Set Up #2 Screen
RESET_COUNTER Button:
Resets the value of
Parts Made to zero.
MAIN:
Select Automatic mode and changes the
screen to Ready to Run [Screen 2].
Screen 65001
Pop Up Screen
This screen appears when the Enter circuit Size
Button has been pressed on Screen 40. Enter the
desired circuit size on the “calculator” screen and
press ENT. Only values between 2 and 12 will be
accepted.
Screen 41
Set Up Screen #2
This screen is displayed when the NEXT button
is pressed on the Set Up #1 Screen.
This screen is displayed when NEXT has been