RAST 5.0 Semi-Automatic Terminator Machine
Doc: No: ATS-623006100
Release Date: 04-28-09
UNCONTROLLED COPY
Page 22 of 65
Revision: A
Revision Date: 04-28-09
Air may have to be removed from the machine to
clear the fault either by pressing Emergency Stop,
opening the guard door or disconnecting the air
supply. If any of these are done their respective
faults (“Emergency Stop”, “Safety Guard Open”, or
“Air Pressure Low”) will take precedence on the
display.
Screen 18
Housing Stick Feed not Forward Fault Screen
This screen is displayed when the Housing Stick
Feed Cylinder fails to activate sensor B0.08. Check
to see if the tooling jammed or if something is
stopping the cylinder from completing its stroke.
Clear the fault and press
CLEAR
button.
Air may have to be removed from the machine to
clear the fault either by pressing Emergency Stop,
opening the guard door or disconnecting the air
supply. If any of these are done their respective
faults (“Emergency Stop”, “Safety Guard Open”, or
“Air Pressure Low”) will take precedence on the
display.
Screen 19
Mask Tooling not Up Fault Screen
This screen is displayed when the Mask Tooling
Cylinder fails to activate sensor B1.00. Check to
see if the tooling jammed or if something is stopping
the cylinder from completing its stroke. Clear the
fault and press
CLEAR
button.
Air may have to be removed from the machine to
clear the fault either by pressing Emergency Stop,
opening the guard door or disconnecting the air
supply. If any of these are done their respective
faults (“Emergency Stop”, “Safety Guard Open”, or
“Air Pressure Low”) will take precedence on the
display.
Screen 20
Mask Tooling not Down Fault Screen
This screen is displayed when the Mask Tooling
Cylinder fails to activate sensor B1.01. Check to
see if the tooling jammed or if something is stopping
the cylinder from completing its stroke. Clear the
fault and press
CLEAR
button.
Air may have to be removed from the machine to
clear the fault either by pressing Emergency Stop,
opening the guard door or disconnecting the air
supply. If any of these are done their respective
faults (“Emergency Stop”, “Safety Guard Open”, or
“Air Pressure Low”) will take precedence on the
display.
Screen 21
Termination Tooling not Up Fault Screen
This screen is displayed when the Termination
Tooling Cylinder fails to activate sensor B1.02.
Check to see if the tooling jammed or if something is
stopping the cylinder from completing its stroke.
Clear the fault and press
CLEAR
button.
Air may have to be removed from the machine to
clear the fault either by pressing Emergency Stop,
opening the guard door or disconnecting the air
supply. If any of these are done their respective