![Mold-Masters TempMaster XL-2 Series User Manual Download Page 21](http://html.mh-extra.com/html/mold-masters/tempmaster-xl-2-series/tempmaster-xl-2-series_user-manual_1823674021.webp)
XL-2 Manual
Running your controller
Revision 1.1
Mold-Masters
®
Page 21
Manual Mode – “Hnd”
When Closed Loop (Auto) mode is not your preferred or the
controller detects thermocouple failure in the system, this mode
helps to continue the operation with constant power output.
1. From the Temperature Display Screen, press and hold for
at least 2 seconds until you get into Function Menu. Manual
mode “Hnd” is the first item in the Function Menu.
2. Confirm your decision by pressing to activate this function,
or to exit without changing operating mode.
3. When Manual Mode is enabled, it goes to Power Display
Screen. Top display is alternating between “Hnd” and actual
temperature reading; bottom shows power percentage.
4. Use
or to adjust to desire power output percentage.
5. To exit from Manual Mode, simply press to get back to
normal operating mode.
Manual mode in each zone activates independently. If both zones
need to be running in this mode, use
to switch to another zone,
repeat the above steps again.
Note:
This feature cannot be disabled completely by setting “EHd”
in program menu to “0” for preventing accidental change of mode.
Boost Mode – “tUP”
This mode provides a means of temporarily boosting the zone
temperature for 2 minutes. To determine the increment, refer to
“Setting Boost Up Level”.
1. From the Temperature Display Screen, press and hold for
at least 2 seconds until you get into Function Menu.
2. Use to scroll to “tUP”.
3. Confirm your decision by pressing
,
or press to exit
without changing operating mode.
4. Once boost mode is enabled, top display is alternating
between “tUP” and actual temperature reading. Bottom
display shows the boost temperature. You may adjust the
boost temperature by using or .
5. To exit from boost mode, simply press to get back to
normal operating mode.
Boost mode in each zone activates independently. If both zones
need to be running in this mode, use
to switch to another zone,
repeat the above steps again.
Note:
This feature cannot be disabled completely by setting “EtU”
in program menu to “0” for preventing accidental change of mode.