iv
• Note the safety labels (examples shown in figure 1) and heed their
warnings.
• The
MSA
or
MOA
must be operated with a controller with keyswitch
interlock. The
MSA
must not be powered unless the keyswitch is
inserted and switched on. It should not be possible to remove the
keyswitch without turning off the power to the
MSA
or
MOA
.
• When the seed laser and amplifier are switched on, there should
be a delay of two seconds before the emission of laser radiation,
mandated by European laser safety regulations (IEC 60825-1).
WARNING
Do not operate the amplifier without sufficient seed laser input. It is
important that an injection seed laser beam is coupled into the ta-
pered amplifier (
TA
) diode so that most of the electrical input energy
is converted to optical output rather than lost as heat, which would
damage the
TA
diode.
NOTE
The
MOGL
abs
MSA
and
MOA
are designed for use in scientific re-
search laboratories. They should not be used for consumer or medical
applications.
Protection Features
The
MOGL
abs
MSA
and
MOA
include a number of features to protect you
and the device. They should be used with a power supply that provides
additional safety features such as key lock operation, current limit, tem-
perature limit, cable continuity and short-circuit detection, soft-start and
turn-on delay.
Protection relay
When the power is off, or the temperature controller is
off, the amplifier diode is shorted via a normally-closed relay.
LED
s
Separate
LED
indicators illuminate when the seed laser and amplifier
diode current supplies are enabled.
Summary of Contents for MOA
Page 4: ...ii ...
Page 14: ...4 Chapter 1 Introduction ...
Page 28: ...18 Chapter 4 MSA internal seed alignment ...
Page 36: ...26 Chapter 5 MOA external seed alignment ...
Page 40: ...30 Chapter 6 Output beam optimisation ...
Page 50: ...40 Chapter 7 Fibre coupling ...
Page 60: ...50 Appendix A Electrical connections ...
Page 63: ...53 MOA C compact amplifier 92 6 95 0 160 50 8 50 0 75 0 76 2 58 ...
Page 64: ......
Page 66: ......