![MOGAS Watson Series Installation, Operation And Maintenance Manual Download Page 24](http://html.mh-extra.com/html/mogas/watson-series/watson-series_installation-operation-and-maintenance-manual_1823360024.webp)
© Copyright 03/31/2021 MOGAS Industries, Inc.
www.mogas.com
24
INSTALL STEM SEAL
Slide the stem seal
08
onto the stem
07
pushing all
the way down so it rests on stem shoulder.
4
5
INSTALL GLAND STUDS
Apply anti-seize compound before inserting the gland
studs
16
. Turn the threads finger tight until they reach
the bottom.
3
16
07
07
Re-Assembly
08
07
04
INSERT STEM
Insert the stem
07
from inside the body
04
and out
through the top stem bore.
If there is a letter stamped on the stem, orientate stem
07
so the letter, which is etched on stem end, faces
the valve’s bottom.