![MOGAS Watson Series Installation, Operation And Maintenance Manual Download Page 13](http://html.mh-extra.com/html/mogas/watson-series/watson-series_installation-operation-and-maintenance-manual_1823360013.webp)
© Copyright 03/31/2021 MOGAS Industries, Inc.
www.mogas.com
13
It is best practice to remove the valve from the piping
system before replacing the packing.
If the valve must remain in-line, it must be isolated
using an approporiate block and bleed arrangement
that is consistent with the system’s hazard
classification. There must be no internal pressure
acting upon the valve or adjacent piping and fittings
prior to gland and packing removal.
ACCESS PACKING
Remove the handle or actuator, and any other
obstruction and expose the top of the stem.
1
Relieve all pressure from the valve and the valve’s
body cavity by cycling a removed valve to the 45°
position, or half open.
REMOVE GLAND FLANGE / THRUSTER
Loosen gland nuts
15
slowly in case there is trapped
pressure in the stem area.
Remove gland flange
10
, followed by gland flange
thruster
09
. Use plyers to work the gland flange
thruster
09
off the stem.
Inspect for corrosion, erosion and damaged surfaces.
2
15
10
04
09
CAUTION!
Do not scratch or create any burrs, which could
cause a leak.
THIS WILL AFFECT THE VALVE WARRANTY.
!