background image

Before attempting to clean the unit, please ensure that the Unit is isolated from 
the electric supply and allowed to cool down, with all food plates and other 
Dishes removed from the unit. 
 
Do not use a water jet or pressure spray to clean this appliance.

1. 

Disconnect trolley from mains and wait until appliance has cooled. 

2. 

Wipe clean using hot, soapy water and soft, non-abrasive cloth. Ensure that the 
stainless steel is wiped in straight strokes following the grain of the material. 

3. 

Wipe dry using a clean cloth. Do not use scouring pads or abrasive cleaners of any 
type. Shelving and select inner panels can be removed to allow a deeper internal 
clean. Ensure all panels and fixings are replaced after cleaning operation. 

4. 

Refrigeration compartment should be washed and then dried with a cloth after 
each service. 

5. 

The chilled well has removable base sections for easy cleaning and maintenance. 
They should be removed periodically and the area beneath wiped clean. 

6. 

The drain holes must also be kept clear from blockage.  

7. 

Wipe down sneeze screen and glass top with a damp, clean cloth. 

8. 

Finish by carefully drying with a soft dry cloth or Kitchen Towels.

17: Cleaning

Do not use scouring pads or abrasive cleaners of any type. 
 
Do not use Solvents, bleach, Caustic Cleaners 
or biological powders on any surface.

Special care should be taken around electrical parts,  
avoided excessive use of water. 
 
Take special care when cleaning glass use a soft duster & glass cleaner spray.

8

Summary of Contents for SDBU

Page 1: ...Manual 018 Issue 001 July 2020 Sanitisers Operating Service Manual Models SDHU SDCU SDRU SDRUCT SDBU SDSU ...

Page 2: ...est results from this unit please take the time to read and follow all safety installation and maintenance guidelines carefully before proceeding to install Keep this manual in a safe place for future consultation These appliances are CE marked in compliance with the relevant Low Voltage EMC Directives Voltage stated on unit data plate Warning Please pay attention to sections of the manual display...

Page 3: ...o the dispensing cable See page 6 to 8 6 Place hand under the dispensing nozzle 8 times to allow the Gel to pump through the unit when the Gel starts to appear continue for an additional 3 times to ensure the system is functioning correctly Do not site in direct sunlight Sun reflection may affect the dispensing sensor NOTE The battery must be charged and discharged three times before the maxi um c...

Page 4: ... the power plug by the power cable 5 If the charger falls or is subjected to some other serious impact have it examined for damage before the next use by a qualified specialist 6 Damaged components must be replaced 7 Handle the battery block with care never allow it to fall 8 Never charge the battery block when the ambient temperature is under 10 C or over 40 C 9 The battery block must not be allo...

Page 5: ...or your screws Remember to use the necessary safety equipment and to also use the correct drill and bit for the surface type Make sure that the screws and wall plugs being used are suitable for supporting the unit Tap in a wall plugs then offer up the unit in place Check the unit is level with a spirit level Fit the unit to the wall and screw in place Do not place any barriers within the hand sens...

Page 6: ...tube is inserted all the way to the bottom of the gel bottle Open the top door and check the battery is plugged in Close the doors remove keys and store them in a safe location Place hand under the dispensing nozzle 20 times to allow the Gel to pump through the unit when the Gel starts to appear continue for an additional 3 times to ensure the system is functioning correctly Note Dispensing volume...

Page 7: ...charging Vertical Gel Tube Spare Gel Bottle Dispensing Nozzel 4 Battery and Gel Connection Models SDHU SDCU SDRU SDRUCRT SDSU 7 Models SDBU Dispensing Nozzel Vertical Gel Tube Battery connection point Spare Gel Bottle Battery lifts out for charging ...

Page 8: ...eper internal clean Ensure all panels and fixings are replaced after cleaning operation 4 Refrigeration compartment should be washed and then dried with a cloth after each service 5 The chilled well has removable base sections for easy cleaning and maintenance They should be removed periodically and the area beneath wiped clean 6 The drain holes must also be kept clear from blockage 7 Wipe down sn...

Page 9: ...9 Battery 12v 7Ah Lead Acid with Fused 2 1mm DC power 12v Lead acid charger 750mA with 2 1mm DC outlet ...

Page 10: ...ffat Ltd Bonnybridge FK4 2BS Scotland Scan the QR code below to visit the E R Moffat website for further information www ermoffat co uk 44 0 1324 812272 sales ermoffat co uk Thank you for choosing E R Moffat ...

Reviews: