Service Procedures
15
5.2.12 Door Removal
1) Remove inner door glass (refer 5.2.11).
2) Whilst supporting the door, unscrew and remove
the top door pivot bolt from the top door hinge
assembly.
5.2.13 Door Hinge
1) Remove door (refer 5.2.12).
2) Remove 2 Hinge plate screws.
Remove Top Door Pivot Bolt.
3) Lift door off bottom hinge.
Remove Top or Bottom
Hinge Screws.
Door Microswitch
Activation Arm
5.3.1 Door
Microswitch
1) Remove back panel.
2) Bend activation arm so switch open circuits when
door is open.
3) Check adjustment when door is opened and
closed.
5.3 Adjustments
5.3.2 Temperature
Calibration
1) Place temperature probe in centre of the oven.
2) Close door and allow temperature to stabilise.
3) Enter service parameters settings menu on con-
trol and check P10 Temperature Offset.