Drawing a Circuit with
“easy”
36
06/99 AWB 2528-1316 GB
Text display (Marker)
The markers can be used to display eight freely
definable texts. Each text block can display up to 48
characters from the easy display character set (ASCII
+ easy special characters). If the coil of a marker is
“1”, the text entered via EASY-SOFT V 2.0 will be
displayed. If several text markers are “1”, the next
text is displayed every 4 seconds. When text marker
D1 is “1” it stays displayed (fault indication).
Press OK to switch to the menus at any time.
Current values or parameters of function relays can
be displayed in lines 2 and 3.
Examples:
Fault signals
Time with text display
Showing scaled analog
values
Display current value and
parameter of timing relay
Display counter value
CAUTION !
PUMP 1
MOTOR
MALFUNCTION
THE TIME
IS
14:42
EXTERNAL
TEMPERATURE
020 0 C
HEAT !
TIMING RELAY
1
SETP99.00 S
ACTV 42.00 S
QUANTITY
ACTV 0042
PCS
SETP0100
For Immediate Delivery call KMParts.com at (866) 595-9616