background image

Modulift UK Ltd  tel: +44(0)1202 621511  email: [email protected]  www.modulift.com

User Instructions

Should you find your equipment is no longer of use, 
please dispose of in a responsible manner. Please 
contact Modulift if you need further guidance

© Copyright 2019 Modulift.  
All rights reserved.

WARNING!

Do not under any circumstances hang load(s) from the tube or flanges 

– the Spreader Frame is designed for compression – not bending.

Ensure that the top Shackle contacts the bow of the corner plate 

‘bow-to-bow’.

The CMOD system is designed in accordance with BS EN13155: 

Cranes, Safety, Non- fixed Load Lifting Attachments.

Max number of Struts: 5 per side on the span without T-Piece, 

8 per side on span with T-Piece.

All Corner Units and T-Pieces must be connected to crane hook 

using top slings and to the load using bottom slings.

All slings must be correctly loaded i.e. no sling (top or bottom) 

to be slack at any point during lift. 

Sling angle is crucial to the safe use of the frame.

The top sling/turnbuckle must be positioned centrally in the 

Shackle pin to ensure even loading. Contact your Modulift 

supplier for supply of loose spacers where required.

T-Pieces must be located opposite each other and must connect 

to struts.

Do’s & Don’ts

Do ensure enough clearance between frame and the load to 

prevent the load hitting the frame. Any collision could cause 

failure of the frame.

Do not exceed the individual WLL of any Corner Unit or T-Piece 

taking into account CoG offsets.

The frame is designed to lift a single solid item using 8 points of 

the frame.

To ensure no slings are slack, use turnbuckles on the central top 

slings, use matching top slings for the corners, and matching 

bottom slings all round. For offset CoGs, or where loads have 

different spans to the frame, more turnbuckles will be required for 

the top and/or bottom slings. Turnbuckles must be adjested until 

all slings are in tension. Contact Modulift for advice if in doubt.

Within side with T-Pieces: Max. distance between the two T-Pieces 

and between T-Pieces and Corner Units to be no more than 50% 

of the total span of that side. Within side without T-Pieces: Min. 

distance between the two T-Pieces and between T-Pieces and 

Corner Units to be no less than 25% of the total span of that side.

When connecting Corner Units directly to T-Pieces, assembly may 

be difficult. Please contact Modulift for assistance.

Do not hang any loads from the Strut tube or flanges.

Do not exceed the stated WLL for your span.

Do not rig the lower slings more than 6° from vertical.

Assembly Procedure

Check the ID plates on each Modulift component to ensure the 

correct size is used.

Lay out the Struts, T-Pieces and Corner Units in the correct 

configuration.

Check all flanges are clear from debris, sand etc. before connection.

Bolt the components together* using bolts, nuts & washers provided. 

Tighten the bolts to torque as shown overleaf.

Loop the top Shackles through the bows of the Corner Units so they 

contact ‘bow-to-bow’. The eye of the top slings can then be passed 

through the jaws of the Shackles and the pins replaced.

Loop the top Shackles through the remaining top slings and connect 

Shackles to the top of the T-Pieces.

Loop the bottom Shackles through the eyes of the drop slings and 

connect to the bottom of the Corner Units and T-Pieces with the 

Shackle pins.

Attach the lower slings to the load to be lifted.

The assembled Spreader Frame and lifting rig must be thoroughly 

checked by a competent person prior to lifting.

*The use of a Podger Spanner will aid in assembly by helping to align the 

bolt holes by forcing it through.

Table 2 – Load v Span

First pick the overall span required for your frame 

(e.g. 1m x 2m) and the Sling Angle (we recommend 

30° STV where possible), then check the WLL via the 

appropriate table. Read the table by locating the 

lower span on the y axis of the chart and the larger 

on the x. The cell which you are referred to, will 

indicate the WLL for your chosen span. If your exact 

span is not noted in the table, then please round up 

or down to the values that will give you the lowest 

WLL (to ensure no overloads are applied). Please 

contact Modulift for confirmation on your WLL if 

required. WLL given in tonnes.

CMOD 50: 8-Point UK JAN 2019

CMOD 50: 8-Point Frame

CMOD 50: 8-Point Frame

  WLL / tonnes @ 30° STV

CMOD 50: 8-Point Frame

  WLL / tonnes @ 45° STV

11

60 50 50 43 32

10

60 60 50 50 41 31

9

60 60 60 50 50 39 29

8

60 60 60 60 50 48 37 28

7

60 60 60 60 60 50 45 35 27

6

60 60 60 60 60 60 50 43 33 26

5

60 60 60 60 60 60 60 50 40 32 25

4

60 60 60 60 60 60 60 50 49 38 31 24

3

60 60 60 60 60 60 60 60 50 47 37 30 23

2

60 60 60 60 60 60 60 60 60 50 45 36 29 23

1

60 60 60 60 60 60 60 60 60 50 44 35 28 22

Span

 

(m)

2

3

4

5

6

7

8

9

10 11 12 13 14 15

11

34 28 28 24 18

10

40 34 28 28 23 17

9

40 40 34 28 28 21 16

8

50 40 40 34 28 27 20 15

7

50 50 40 40 34 28 25 19 14

6

50 50 50 40 40 34 28 24 18 14

5

50 50 50 50 40 40 34 28 23 17 13

4

50 50 50 50 50 40 40 28 28 21 17 13

3

50 50 50 50 50 50 40 40 28 26 21 16 12

2

50 50 50 50 50 50 50 40 34 28 28 20 16 12

1

50 50 50 50 50 50 50 40 34 28 25 20 15 12

Span

 

(m)

2

3

4

5

6

7

8

9

10 11 12 13 14 15

Side with T-Piece

Side with T-Piece

Side 

without T

-P

iec

e

Side 

without T

-P

iec

e

Reviews: