MODULE-AIR AF-36 VT Series Operating Instructions & Parts Manual Download Page 4

Module-Air 

Revised 03-01-2018 

 

 

12. Maintain the unit in top 
condition.  Clogged filters can 
increase potential for fire or 
explosion.  Follow instructions for 
changing filters.   

 

13. Turn the unit “off” and 

disconnect power source before 
installing or removing accessories, 
before adjusting or changing set-
ups or when making repairs.  An 
accidental start up can cause 
serious injury. 

 

14. Explosion relief vents are 
required for some applications.  
Consult with an insurance 
underwriter or an NFPA manual to 
determine proper vent size and 
ratio.  Module-Air LLC DOES NOT 
CONTAIN EXPLOSION RELIEF 
VENTS as shipped from the factory 
and must be field installed per 
NFPA standards.   

 

15. The AF-36xxVT series units are 
made to run continuously, check 
the filters regularly for built-up 
debris.  Frequency of filter 
changes will depend upon the 
environment in which the unit is 
running. 

 

16. To maintain warranty, be sure 
to use only filters that are 
approved by the manufacturer. 

 

INSTALLATION AND 
PREPARATION BEFORE 
OPERATING: 
Disclaimer: 

Although instructions and 
recommendations are included for 
installation of your Module-Air air 
filtration system, the 
manufacturer does not assume 
responsibility for the installation 
of this equipment nor shall be 
held liable for direct or 
consequential damages resulting 
from improper methods, 
structural failure or inadequate 
supports. 
 
 

Installation: (Diagram on PG. 5) 

Installation methods will depend 
upon the style of intake options 
that were selected when your 
system was ordered.  The 
following is a basic guide line and 
only a suggestion.  A professional 
installer should be consulted. 
     One option is to mount Uni-
Strut to the building structure, 
dangle threaded rod through the 
holes in the strut with a nut and 

washer 6” down and under the 

strut.  Lift the unit up until the top 
of the unit taps the threaded rod.  
Thread the connector nuts onto 

the ½” studs provided in the top of 

the unit.  

Start a ½” nut on the 

threaded rod to be used as a jam 
nut.   
  Now screw the threaded rod into 
the connector nuts and tighten up 
the jam nuts.   
  The unit can now be lowered and 
the nuts under the strut can be 
tightened up to finish the 
suspension. 

The unit can also be 

mounted on the wall with a simple 
angle frame, as shown in fig 1. on 
page 5.  
The uni-strut rails, nuts, and 
threaded rods are not provided 
with the units. (Uni-strut is 
available through several places, 
such as Grainger).  . 
Again, mounting instructions are 
only a suggestion.  Module-Air is 
indemnified from any liability 
related to improper installation.  
Improper installation could result 
in person injury and/or damage to 
the unit.   
 

Noise Declaration 

The figures shown are emissions 
levels and are not necessarily safe 
working levels.  While there is a 
correlation between the emission 
and exposure levels, this cannot 
be used reliably to determine 
whether or not further 
precautions are required.   

 

 

 