5
•
If the output (white) 10mm² cable needs to be extended beyond 4 meters, it should be replaced
at the battery charger by 10mm² cable and can be extended up to 9 meters.
•
Beyond 9 meters, it should be replaced at the battery charger by 16mm² cable (up to a maximum
total length of 10 meters).
The 1mm² ignition positive (+) (brown) cable can be extended beyond 5 meters by the same 1mm²
cable, as this cable draws very little load.
Modul-Connect Battery Charger Installation:
•
Choose an appropriate mounting location.
•
All fuses, fuse holders and connecting cables are supplied with the product.
•
This battery charger shall be mounted and connected as close to the auxiliary battery (which is
being charged) as possible.
•
The battery charger must be securely mounted on a metal or non-combustible surface.
•
Use a mounting template to mark the positions of the mounting screws.
•
The battery charger has 4 off fixing holes (6.5mm diameter) and 4 off fixing slots (6mm x 10mm)
for ease of mounting.
•
It is recommended to use a minimum of 4 off M5 fixings to secure the battery charger.
•
Drill the 4 mounting holes, place the charger in position and fasten it to the mounting surface.
IMPORTANT: Connection Procedure / Power up sequence to ensure normal operations:
1.
Remove all in-line fuses from the fuse holders.
2.
Connect the charger negative cable (black) to the battery negative or chassis earth.
3.
Connect the charger input cable (red) to the chassis battery.
4.
Connect the positive remote input cable (brown) to the ignition supply using supplied cables and
fuse holder.
5.
Connect the auxiliary battery positive cable (white) to the auxiliary battery.
6.
Insert 50A chassis battery fuse.
7.
Insert the 2A fuse into the ignition feed.
If this order is not followed the unit may flash amber for up to 10 minutes at key on (even if the
auxiliary battery is fully charged). After the elapsed time the Modul-Connect Battery Charger will