CONTROLS AND FEATURES / MECHANICAL SPECIFICATIONS

Figure 6.1

Controls and Features

Unit Mechanical Specifications

     One-Piece Cabinet Top and Sides (STD)

   Cabinet top and sides are formed from a single sheet of 18 

gauge steel reducing the number of parting lines common to 

multi-piece construction. Fronts are 16 gauge. All louvers are 

stamped as standard.

➁  

Wrap-Around Partitions and Back Sheet (STD)

   Inner partition panels and back sheet are die-formed from a 

single sheet of 18 gauge steel. This assures precision fit and 

alignment of all internal components and maximum cabinet 

rigidity.

➂  

All-Welded Construction (STD)

   Cabinet unit heaters utilize five to eight structural 

components in the basic cabinet. The components are 

fixture-aligned and welded.

➃  

Cabinet End Pockets (STD)

   The two cabinet end pockets provide ample space for 

convenient installation of piping and electrical wiring. Easy 

access reduces costs and installation time.

➄   

Cabinet Finish (STD)

   After assembly and welding operations are completed, 

the entire cabinet unit is treated for prevention of rust and 

corrosion. Entire cabinet is finished with a tan color, durable 

polyester powder-coat paint.

➅   

Quick-Change Permanent Filters (STD)

   Filters are removable without tools. After opening the unit’s 

front panel, the filter easily slides out. Cleanable filters are 

provided as standard.

➆  

Insulation (STD)

  Sound dampening insulation on all front panels.

➇   

Coils – Steam/Hot Water (STD)

   All coils used in cabinet heaters use copper tube, aluminum 

fin construction with NPT connections; 3/4" for sizes 2 thru 6, 

and 1" for sizes 8 thru 14. Tubes are mechanically expanded 

into integral fin collars. Return bends and joints are silver 

alloy brazed and the coil is pressure-tested to 200 psig 

pressure. Field reversible coils allow piping to be made for 

left or right side connection, with left hand piping as factory 

standard.

➈  

Power Assembly (STD)

   Blower platform, blower, and blower motor on all sizes are 

removable as a single unit. A direct drive, multi-speed, 

shaded pole motor with built in thermal overload protection 

powers the forward curved aluminum blower wheels. Right 

hand electrical as factory standard.

➉   

Speed Control (STD)

  Solid state infinite speed control with off position.

 

Access Doors (not shown) (STD)

  Tilt type access doors standard on model FC units.

11

Cabinet

Floor models shall be provided with stamped louvers and a one 

inch high dust barrier at the bottom. The cabinet shall be 18-gauge 

steel with 16 gauge front panels. All painted surfaces shall be 

treated for corrosion resistance prior to being finished with a tan, 

baked on enamel finish, which may be used as a final coat or 

repainted. All unpainted steel shall be galvanized. (When specified) 

color as selected by architect shall be provided in one of 9 optional 

colors as shown on manufacturer’s color chart 75-403.
Wall or ceiling models shall have cabinets with stamped louvers. 

The entire bottom of the unit must be enclosed. Access to the speed 

control shall be through the easy access 16-gauge front panels.
(Available, when specified, as optional equipment) an access 

door shall be provided for speed control access.
All models shall have two 9" minimum wide piping end pockets. 

All wall and ceiling units shall have safety hinged access panels 

that can be easily removed during installation.

Coils

The heating coils shall provide specified capacities and not 

exceed the pressure drop and GPM listed in this catalog. 1 & 2 

row coils shall be suitable for 200 PSIG working pressure with 

240°F water. 3 & 4 row coils shall be suitable for 200 PSIG 

working pressure with 200°F water.
Steam pressure shall not exceed 10 psig on 1 row coils.

Motor Speed Control

The unit shall have a unit-mounted solid state motor speed control, 

with high through low speeds and off positions on all models.

Summary of Contents for Model FC series

Page 1: ...nsers are warranted for operation at hot water pressures up to 200 lbs per sq in gauge and or temperatures up to 240 F or steam pressures up to 10psig for one row coils only The 3 4 row condensers are...

Page 2: ...blanketed by their air streams 8 Mounting height is critical for optimum performance Refer to Mounting Height on page 4 before installation WARNING 1 Disconnect power supply before making wiring conn...

Page 3: ...ring must comply with CSA C22 1 Electrical Code 2 Electric wiring must be sized to carry the full load amp draw of the motor and any controls that are used with the unit heater Overcurrent protectors...

Page 4: ...unit heaters when operated with steam pressures other than 2 pounds or with water at other than entering temperature of 220 F 1 3 1 2 1 1 1 0 9 8 7 6 5 CORRECTION FACTOR R AVERAGE WATER TEMP F 150 160...

Page 5: ...Arrangement 98 Model CW Arrangement 97 Model CW Arrangement 96 Model CW Arrangement 90 Model CW Arrangement 00 Model CW Arrangement 06 Model CW Arrangement 07 Model CW Arrangement 58 Model CW Arrangem...

Page 6: ...r left or right side connection with left hand piping as factory standard Power Assembly STD Blower platform blower and blower motor on all sizes are removable as a single unit A direct drive multi sp...

Page 7: ...NPT 1 NPT 1 NPT 1 NPT Blowers Direct Drive No Dia x Width Inches 1 5 1 4 x 7 1 5 3 4 x 7 2 5 1 4 x 7 2 5 3 4 x 7 3 5 3 4 x 7 3 5 3 4 x 7 4 5 3 4 x 7 4 5 3 4 x 7 High Speed Rpm 1625 1625 1625 1625 1625...

Page 8: ...12 10 7 5 7 8 47 5 8 39 5 8 9 3 4 205 012 83 3 4 28 12 10 7 5 1 8 59 5 8 51 5 8 9 3 4 240 014 83 3 4 28 12 10 7 5 7 8 59 5 8 51 5 8 9 3 4 240 Unit Size Approx Unit Weight lbs Figure 8 1 Floor Model FC...

Page 9: ...3 4 240 014 83 3 4 28 12 5 7 8 59 5 8 9 3 4 240 Table 9 1 Cabinet Dimensions inches Table 9 2 Filter Dimensions inches Model Size Filter Size 002 8 1 2 x 20 3 4 x 1 2 003 8 1 2 x 25 3 4 x 1 2 004 8 1...

Page 10: ...COIL CONNECTION DIMENSIONS 3 4 ROW COIL UNITS Table 10 1 10...

Page 11: ...Duct Collar Table 11 2 Model FC 25 and 100 Fresh Air Duct Collar All dimensions are in inches Includes 3 4 top and bottom duct flanges for duct connection Outside Air Percentage 25 100 1 3 or 6 2 4 o...

Page 12: ...cleaned frequently Do not use any commercial solvent that could deteriate the coil and do not use any liquid or steam sprays that could damage electrical components Good filter maintenance will minimi...

Page 13: ...SHIPMENT FROM SELLER These warranties are issued only to the original owner user and cannot be transferred or assigned No provision is made in these warranties for any labor allowance or field labor p...

Reviews: